OWNER’S MANUAL
TROUBLESHOOTING
WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.
FAULT CONDITION | POSSIBLE CAUSE | REMEDY | |||
Motor does not start five seconds after heater | 1. | No power to heater | 1. | Check circuit breaker in electrical panel. | |
is plugged in. |
|
|
|
|
|
|
| WARNING: High voltage! |
| ||
|
|
|
| ||
|
|
|
|
|
|
| 2. | Bad electrical connection between mo- | 2. | Check all electrical connections. See | |
|
| tor and ignition control assembly or ig- |
| Wiring Diagrams, page 10. | |
|
| nition assembly and power cord |
|
| |
| 3. | Binding pump rotor | 3. | If fan does not turn freely, see Pump Ro- | |
|
|
|
|
| tor, page 8. |
| 4. | Defective ignition control assembly | 4. | Replace ignition control assembly. | |
| 5. | Defective motor | 5. | Replace motor. | |
|
|
|
|
| |
Motor starts and runs but heater does not | 1. | No fuel in tank | 1. | Fill tank with kerosene. | |
ignite. | 2. | Pump pressure incorrect | 2. | See Pump Pressure Adjustment, page 6. | |
| 3. | Dirty fuel filter | 3. | See Fuel Filter, page 7. | |
| 4. | Obstruction in nozzle | 4. | See Nozzle, page 8. | |
| 5. | Water in fuel tank | 5. | Drain and flush fuel tank with clean | |
|
|
|
|
| kerosene. See Storing, Transporting, or |
|
|
|
|
| Shipping, page 4. |
WARNING: High voltage!
6.Bad electrical connection between igni- tor and ignition control assembly
7.Defective ignitor
8.Defective ignition control assembly
6.Check electrical connections. See Wir- ing Diagrams, page 10.
7.Replace ignitor, see page 7.
8.Replace ignition control assembly.
Heater ignites but ignition control assembly | 1. | Pump pressure incorrect | 1. | See Pump Pressure Adjustment, page 6. | |
shuts heater off after a short period of time. | 2. | Dirty air intake, air output, and/or lint | 2. | See Air Output, Air Intake, and Lint Fil- | |
|
| filter |
| ters, page 6. | |
| 3. | Dirty fuel filter | 3. | See Fuel Filter, page 7. | |
| 4. | Obstruction in nozzle | 4. | See Nozzle, page 8. | |
| 5. | Photocell assembly not properly in- | 5. | Make sure photocell boot is properly | |
|
| stalled (not seeing the flame) |
| seated in bracket. | |
| 6. | Dirty photocell lens | 6. | Clean photocell lens. | |
|
|
|
|
| |
|
|
| WARNING: High voltage! |
| |
|
|
|
|
|
|
| 7. | Bad electrical connection between pho- | 7. | Check electrical connections. See Wir- | |
|
| tocell and ignition control assembly |
| ing Diagrams, page 10. | |
| 8. | Defective photocell | 8. | Replace photocell. | |
| 9. | Defective ignition control assembly | 9. | Replace ignition control assembly. |
102388 | 5 |