![CONNECTING TO GAS SUPPLY](/images/new-backgrounds/46219/4621921x1.webp)
OWNER’S MANUAL
INSTALLATION
Continued
8.Reattach heater base to mounting brackets. Tighten nuts firmly.
9.Connect to gas supply. See Connect- ing To Gas Supply.
Heater Gas
Regulator
Flexible Gas Hose (if allowed by local codes)
Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator
Masonry
Screw
Mounting | Mounting |
| |
Bracket | Mounting | ||
Bracket Nut | |||
Screw | |||
| Bracket | ||
|
|
Figure 12 - Attaching Heater to Fireplace Floor
CONNECTING TO GAS SUPPLY
WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.
Installation Items Needed
Before installing heater, make sure you have the items listed below.
•piping (check local codes)
•sealant (resistant to propane/LP gas)
•manual shutoff valve *
•test gauge connection *
•sediment trap
•tee joint
•pipe wrench
*An A.G.A.
WARNING: Never connect heater to private
CAUTION: Use only new, black iron or steel pipe. Inter-
Installationmustincludeamanualshutoffvalve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13).
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.
We recommend that you install a sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contami- nants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.
From Gas Meter | A.G.A. | |
Shutoff Valve With 1/8" NPT Tap* | ||
(5" W.C.** to 10.5" | ||
| ||
W.C. Pressure) |
|
Approved Flexible Gas Hose (if allowed by local codes)
| Tee |
|
|
Sediment | Joint |
|
|
Pipe |
|
| |
Trap |
|
| |
Nipple |
| Gas | |
| 3" Minimum | ||
|
| ||
| Cap | Regulator | |
|
|
Figure 13 - Gas Connection
* Purchase the optional A.G.A.
** Minimum inlet pressure for purpose of input adjustment.
Continued
104414 | 11 |