CONNECTING TO GAS SUPPLY

OWNER’S MANUAL

INSTALLATION

Continued

8.Reattach heater base to mounting brackets. Tighten nuts firmly.

9.Connect to gas supply. See Connect- ing To Gas Supply.

Heater Gas

Regulator

Flexible Gas Hose (if allowed by local codes)

Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator

Masonry

Screw

Mounting

Mounting

 

Bracket

Mounting

Bracket Nut

Screw

 

Bracket

 

 

Figure 12 - Attaching Heater to Fireplace Floor

CONNECTING TO GAS SUPPLY

Manual background WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

piping (check local codes)

sealant (resistant to propane/LP gas)

manual shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 28.

Manual background WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

Manual background CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

Installationmustincludeamanualshutoffvalve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13).

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

Manual background CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

We recommend that you install a sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contami- nants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Manual background CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

From Gas Meter

A.G.A. Design-Certified Manual

Shutoff Valve With 1/8" NPT Tap*

(5" W.C.** to 10.5"

 

W.C. Pressure)

 

Approved Flexible Gas Hose (if allowed by local codes)

 

Tee

 

 

Sediment

Joint

 

 

Pipe

 

 

Trap

 

 

Nipple

 

Gas

 

3" Minimum

 

 

 

Cap

Regulator

 

 

Figure 13 - Gas Connection

* Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 28.

** Minimum inlet pressure for purpose of input adjustment.