Desa B, C Variable Control Operation, Desa International, Unvented Natural Gas Log Heater

Models: CFS24NVC VS30N B, C

1 30
Download 30 pages 50.94 Kb
Page 16
Image 16
VARIABLE CONTROL

DESA INTERNATIONAL

UNVENTED NATURAL GAS LOG HEATER

OPERATING

HEATER

Continued

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation page 15, column 2. If you don’t smell gas, go to the next step.

5.Press in control knob and turn coun-

terclockwise ClockwiseManual background to the PILOT po- sition. Keep control knob pressed in for five (5) seconds (see Figure 22, page 15).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep press- ing ignitor button until pilot lights.

Note: If pilot does not light, contact a qualified service person or gas sup- plier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Light- ing Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7.

8.Push in and turn control knob coun- terclockwise to the HIGH position. Both burners should light. Set con- trol knob to desired setting.

Ignitor Electrode

Thermocouple

Pilot Burner

Figure 23 - Pilot

VARIABLE CONTROL

OPERATION

The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides realistic flames and glow- ing embers from two burners. Selecting higher settings produces greater heat output. This results in increased heating comfort.

Manual background WARNING: Do not operate heater between locked positions.

Manual background CAUTION: Do not try to ad- just heating levels by using the manual shutoff valve.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Press in and turn control knob clock-

wise ClockwiseManual background to the HIGH position.

2.Turn the control knob clockwise ClockwiseManual background to the PILOT position.

3.Press in control knob and turn clock-

wise

Clockwise

to the OFF Position.

 

 

Shutting Off Burners Only (pilot stays lit)

1.Turn the control knob clockwise ClockwiseManual background to the HIGH position.

2.Press in and turn control knob clock-

wise ClockwiseManual background to the pilot position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Light- ing Instructions, pages 15 and 16.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, column 2.

16

104414

Page 16
Image 16
Desa B, C Variable Control Operation, Desa International, Unvented Natural Gas Log Heater, Operating Heater, Continued