Desa CBT20NT, CBP30T Continued, Observed Problem, Possible Cause, Remedy, and Maintenance, page

Models: SBP20 SBN20 CBN20T CBP20 CBT30PT CBP20TK CBT20NT CBN30T CBT30NT CBP20T CBN20TK CBT20PT CBP30T CBN20, CBP20, SBN20, SBP20, CBN20T, CBP20T, CBN30T, CBP30T, CBT20NT, CBT20PT, CBT30NT, CBT30PT, CBN20TK, CBP20TK

1 32
Download 32 pages 19.03 Kb
Page 20
Image 20
and Maintenance, page 17)

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

ODS/pilot lights but flame

1. Control knob not fully pressed in

1.

Press in control knob fully

 

goes out when control knob is

2. Control knob not pressed in

2. After ODS/pilot lights, keep con-

released

 

long enough

 

trol knob pressed in 30 seconds

 

3.

Safety interlock system has

3.

Wait one minute for safety in-

 

 

been triggered

 

terlock system to reset. Repeat

 

4.

Equipment shutoff valve not

 

ignition operation

 

4.

Fully open equipment shutoff

 

 

fully open

 

valve

 

5.

Thermocouple connection

5.

Hand tighten until snug, then

 

 

loose at control valve

 

tighten 1/4 turn more

 

6.

Pilot flame not touching

6.

A) Contact local natural or

 

 

thermocouple, which allows

 

propane/LP gas company

 

 

thermocouple to cool, caus-

 

B) Clean ODS/pilot (see

 

 

ing pilot flame to go out. This

 

 

 

problem could be caused by

 

Cleaning and Maintenance,

 

 

one or both of the following:

 

page 17) or replace ODS/pilot

 

 

A) Low gas pressure

 

assembly

 

 

B) Dirty or partially clogged

 

 

 

 

 

ODS/pilot

 

 

 

 

7.

Thermocouple damaged

7.

Replace pilot assembly

 

8.

Control valve damaged

8.

Replace control valve

 

 

 

 

 

 

Burner does not light after ODS/

1.

Burner orifice is clogged

1.

Clean burner (see Cleaning

 

 

 

and Maintenance, page 17)

pilot is lit

 

 

 

or replace burner orifice

 

2.

Inlet gas pressure is too low

2.

Contact local natural or pro-

 

 

 

 

pane/LP gas company

 

 

 

 

 

 

 

1.

Manifold pressure is too low

1.

Contact local natural or pro-

Delayed ignition of burner

 

 

 

pane/LP gas company

 

2.

Burner orifice is clogged

2.

Clean burner (see Cleaning

 

 

 

 

and Maintenance, page 17)

 

 

 

 

or replace burner orifice

 

 

 

 

 

 

 

1.

Burner orifice is clogged or

1.

Clean burner (see Cleaning

Burner backfiring during

 

damaged

 

and Maintenance, page 17)

combustion

2.

Burner damaged

 

or replace burner orifice

 

2.

Replace burner

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

 

 

1.

Not enough air

1.

Check burner for dirt and de-

Yellow flame during burner

 

 

 

bris. If found, clean burner (see

combustion

 

 

 

Cleaning and Maintenance,

 

2.

Gas regulator defective

 

page 17)

 

2.

Replace gas regulator

 

3.

Clogged or dirty burner

3.

Clean burner (see Cleaning

 

 

 

 

and Maintenance, page 17)

 

 

 

 

 

Slightsmokeorodor duringinitial

1. Residues from manufacturing

1.

Problem will stop after a few

operation

 

processes

 

hours of operation

20

www.desatech.com

107882-01K

Page 20
Image 20
Desa CBT20NT, CBP30T, CBT20PT, CBN20TK, CBP20T Continued, Observed Problem, Possible Cause, Remedy, and Maintenance, page