Desa CBP20TK, CBP30T, CBT20PT, CBN20TK, CBT30NT Air For Combustion And Ventilation, Installation

Models: SBP20 SBN20 CBN20T CBP20 CBT30PT CBP20TK CBT20NT CBN30T CBT30NT CBP20T CBN20TK CBT20PT CBP30T CBN20, CBP20, SBN20, SBP20, CBN20T, CBP20T, CBN30T, CBP30T, CBT20NT, CBT20PT, CBT30NT, CBT30PT, CBN20TK, CBP20TK

1 32
Download 32 pages 19.03 Kb
Page 7
Image 7
INSTALLATION

AIR FOR COMBUSTION

AND VENTILATION

Continued

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining un- confined space. When ventilating to an adjoining unconfined space, you must provide two perma- nent openings: one within 12” of the ceiling and one within 12” of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12” of the ceiling and one within 12” of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat- controlled power vent. Heated air entering the attic will activate the power vent.

 

Outlet

Ventilated

 

Attic

 

Air

 

 

Outlet

 

 

Air

 

To Attic

 

 

 

 

To

 

 

Crawl

Inlet

 

Space

 

 

Air

 

 

 

Inlet Air

Ventilated

 

Crawl Space

 

 

Figure 3 - Ventilation Air from Outdoors

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

Manual background WARNING: A qualified ser- vice person must install heater. Follow all local codes.

Ventilation

 

Grills

Or

into Adjoining

Remove

Room,

Door into

Option 1

Adjoining

 

Room,

 

Option 3

12"

Ventilation Grills

Into Adjoining Room,

Option 2

CHECK GAS TYPE

Use only the correct type of gas (natural or pro- pane/LP). If your gas supply is not the correct gas type, do not install heater. Call dealer where you bought heater for proper type heater.

Manual background WARNING: This appliance is equipped for (natural or pro- pane/LP) gas. Field conversion

12"

is not permitted.

Figure 2 - Ventilation Air from Inside

Building

107882-01K

www.desatech.com

7

Page 7
Image 7
Desa CBP20TK, CBP30T, CBT20PT, CBN20TK, CBT30NT, CBN30T, CBT20NT, CBT30PT, SBN20 Air For Combustion And Ventilation, Installation