SELECTING LOCATION

SELECTING LOCATION PRE-INSTALLATION PREPARATION

Clearances to Combustibles

Mantel Clearances

3

SELECTING LOCATION

To determine the safest and most efficient location for your fire- place, consider the following guidelines:

1.The location must allow for proper clearances (see Figure 1).

2.Consider a location where the firepace would not be affected by drafts, air conditioning ducts, windows or doors.

3.A location that avoids the cutting of joists or roof rafters makes ventilation installation easier.

In selecting a location, the following precautions must be observed:

Do not connect this appliance to a chimney system used for solid fuel burning fireplace.

Due to high temperatures, do not locate this appliance in high traffic areas or near furniture and draperies.

Never obstruct the openings of the appliance or flow of ventila- tion air. Keep the control compartments accessible.

Do not locate appliance close to where gasoline or other flam- mable liquids may be stored. The appliance must be kept clear and free from combustible materials.

Do not use this appliance if any part has been under water. Imme- diately contact a local service technician to examine the appli- ance and to replace any part(s) of the control ignition system and other related components that have been submerged under water.

PRE-INSTALLATION

PREPARATION

PRE-INSTALLATIONCAUTION: Do not block required air spaces with insulation or any other material. Do not obstruct the effective opening of the appliance with any type of facing material.

CLEARANCES TO COMBUSTIBLES

Minimum clearances to combustibles for the fireplace are:

 

• Back and Sides of Fireplace

0"

Floor

0"

Perpendicular Wall

6"

Front

36"

Top of Standoffs

0"

MANTEL CLEARANCES

Woodwork, such as wood trims, mantles, and other combustible materials should be placed within the required clearance specified in Figure 2.

FULL

PROJECTION

CORNER

INSTALLATION

FLUSH

INSTALLATION

Figure 1 - Common Fireplace Locations

Flush installation is recommended where living space is limited.

Projected installation may be ideal for a new addition to an existing finished wall.

Corner installation makes use of a space that may not normally be used and provides a wider and more efficient range for radiant heat transfer.

 

 

 

1

 

 

 

2

 

 

 

3

A

 

 

Wall

 

 

 

 

 

 

4

B

 

 

5

 

C

 

6

 

 

 

 

 

D

 

 

 

E

7

 

 

 

 

 

 

F

 

 

 

G

 

 

Top of Louver Opening

Mantel

Mantel From Top

Depth

of Opening

 

 

 

(1)

14"

(A) 16"

(2)

12"

(B) 14"

(3)

10"

(C) 12"

(4)

8"

(D) 10"

(5)

6"

(E) 8"

(6)

4"

(F) 6"

(7)

2"

(G) 4"

 

 

 

Figure 2 - Mantel Clearances

CLEARANCES TO COMBUSTIBLESMANTEL CLEARANCESManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background