GAS SUPPLY TESTING

INSTALLATION

Venting Installation (Con.)

Electrical Gookup and Remote Reeiver Diagram

Gas Supply Testing

7

INSTALLATION

Continued

If an offset is necessary in the attic to avoid obstruction, it is important to support the vent pipe every 3 ft. to avoid excessive stress on the elbows and possible separation (see Figure 8, page 7).

Clearances must be maintained between the roof and the ter- mination. Refer to chart below.

Roof Pitch

Minimum Height Above Roof

 

 

Flat - 7/12

1 ft. (30.48 cm)

7/12 - 8/12

1 1/2 ft. (45.72 cm)

8/12 - 9/12

2 ft (60.96 cm)

9/12 - 10/12

2 1/2 ft (76.20 cm)

10/12 - 11/12

4 ft (121.92 cm)

11/12 - 14/12

5 ft (152.40 cm)

14/12 - 16/12

6 ft (182.88 cm)

16/12 - 18/12

7 ft (213.36 cm)

18/12 - 20/12

7 1/2 ft (228.60 cm)

20/12 - 21/12

8 ft (243.84 cm)

 

 

Roof Flashing

Outlet Box ELECTRICAL HOOKUP AND REMOTE RECEIVER DIAGRAM

Three-prong Plug

Figure 9 - Duplex Outlet

 

 

TH

 

PI L

 

 

OT

TP

O

 

ON

 

 

T

 

 

L

 

 

I

 

 

P

 

 

OFF

 

TPTH

 

TH

Convertible

TP

 

TPTH

 

Gas Valve

REMOTE

OFF

 

 

ON

 

 

Remote Control

Receiver

Figure 10 - Remote Control Receiver

GAS SUPPLY TESTING

NOTICE: This section is intended as a guide for qualified technicians installing gas to the appliance.

Wall Strap Manual background

45° Elbows

Ceiling Firestop

Figure 8 - Vertical Termination with Offset and Wall Strap

ELECTRICAL HOOKUP AND REMOTE RECEIVER DIAGRAM

An outlet box with two receptacles (see Figure 9) has been supplied for your convenience and is located inside on the lower right side of the fireplace.

The remote control receiver is factory wired and connected to the convertible gas valve as shown in Figure 10.

Manual background WARNING: Do not connect appliance before pres- sure testing gas piping. Damage to gas valve may result and an unsafe condition may be created.

The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

The gas control valve is secured underneath the firebox. Two 1/8" ports are provided on the gas control valve for pressure test gauge connections (see Figure 11).

 

 

Pilot Adjustment

 

To Pilot Burner

 

 

 

 

ON/OFF

 

 

 

ILOT

 

Pilot Gas

Knob

 

 

 

 

Line Do

 

 

 

P

 

 

 

N

 

16AI

 

 

 

 

O

 

 

Not Kink

 

P

 

 

 

 

O

T

 

 

TH

 

 

 

 

7

 

 

I

 

 

 

L

 

 

 

 

 

 

 

L

I

 

To Main

 

 

FFO

O

H

TP

 

 

 

E

A

 

TPTH

Burner

Inlet

 

 

 

 

 

 

 

Flame Adjustment Knob

Pressure

 

 

 

Outlet Pressure

 

 

 

 

 

Figure 11 - Gas Control Valve

 

 

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111916-01D

Page 7
Image 7
Desa CD36M, CD32M, CD42M Installation, Continued, Gas Supply Testing, Electrical Hookup And Remote Receiver Diagram