WIRING DIAGRAM SPECIFICATIONS REPLACEMENT PARTS

31

WIRING DIAGRAM

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Variable

Fan SwitchFan Switch

(N.O.)

Off 1

2

Black

 

On

 

Blue

110/115

V.A.C.

Black

Blower

 

White

Motor

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 61 - Blower Wiring Diagram for Thermostat-Controlled Models

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can not supply original replacement part(s), call DESA International’s Technical Service Department at 1-866-672-6040.

When calling DESA International, have ready

your name

your address

model and serial numbers of your burner system and stove

how burner system or stove was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can not supply original replacement part(s), call DESA International at 1-866-672-6040 for referral information.

When calling DESA International, have ready

model number of your burner system and stove

the replacement part number

SPECIFICATIONS

 

CDVBN(A)

CDVBP(A)

 

16,000-22,000 Btu/hr

14,000-20,000 Btu/hr

 

 

 

Gas Type

Natural

Propane/LP

 

 

 

Ignition

Piezo

Piezo

 

 

 

Manifold Pressure

3.5" w.c.

10.0" w.c.

 

 

 

Minimum Inlet Supply Pressure

4.5" w.c.

11.0" w.c.

 

 

 

Thermal Efficiency

70%

70%

 

 

 

Dimension, Inches/mm (HxWxD)

 

 

Stove and Burner System*

26 1/2" x 25" x 25 5/8"

26 1/2" x 25" x 25 5/8"

 

673.1 x 635 x 650.7mm

673.1 x 635 x 650.7mm

Carton (Insert Only)

23 1/4" x 33 1/4" x 23 1/2"

23 1/4" x 33 1/4" x 23 1/2"

 

590.5 x 844.5 x 596.9mm

590.5 x 844.5 x 596.9mm

 

 

 

Weight, lbs/kg

 

 

Burner System

70 lbs/31.8 kg

70 lbs/31.8 kg

Shipping

75 lbs/34 kg

75 lbs/34 kg

 

 

 

* When installed in Comfort Glow cast iron stove body (CISGA Series and CISCA Series).

For morevisit www..com

105501-01F

Page 31
Image 31
Desa CDVBPC, CDVBNC Wiring Diagram, Replacement Parts, Specifications, Parts Under Warranty, Parts not Under Warranty