CONNECTING STOVE/ BURNER SYSTEM TO GAS SUPPLY
Installation Items Needed
•5/16" hex socket wrench or
•sealant (resistant to propane/LP gas, not provided)
1.Open lower door panel.
2.Route flexible gas line (provided by installer) from manual shutoff valve to burner system. Route flexible gas sup- ply line through slot in stove bottom and attach to valve.
3.Check all gas connections for leaks. See Checking Gas Connections.
CHECKING GAS
CONNECTIONS
WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once.
WARNING: Never use an open flame to check for a leak. Apply commercial leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.
Pressure Testing Gas Supply Piping System
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
1. | Disconnect burner system and its |
| individual manual shutoff valve from |
| gas supply piping system. Pressures in |
| excess of 1/2 psig (3.5 kPa) will |
| damage burner system gas regulator. |
2. | Cap off open end of gas pipe where |
To Flare Fitting on Control Valve
Manual Shutoff Valve |
| |
| To Gas Supply | |
Flexible Gas Line from | (Natural) | |
| ||
Manual Shutoff Valve | To External | |
Provided by Installer | ||
Regulator | ||
| ||
| (Propane/LP) |
manual shutoff valve was connected. |
3. Pressurize supply piping system by ei- |
ther opening propane/LP supply tank |
valve for propane/LP gas burner sys- |
tem or opening main gas valve located |
on or near gas meter for natural gas |
burner system, or using compressed air. |
4. Check all joints of gas supply piping |
system. Apply commercial leak test so- |
lution to all gas joints. Bubbles forming |
Figure 40 - Flexible Gas Line
show a leak. Correct all leaks at once. |
5. Reconnect burner system and manual |
shutoff valve to gas supply. Check re- |
connected fittings for leaks. |
Continued