INSTALLING REAR COVER

1.Lift rear panel over vent pipe connec- tion on burner system. Rear cover will rest on the bottom ledge of the stove body.

2.Using screws provided, attach rear cover to back of stove body. See Fig- ure 17.

IMPORTANT: This rear cover must be securely in place before venting pipes are installed.

Rear

Cover

GENERAL VENTING

These models are approved for use with Simpson Dura-Vent 6 5/8" direct-vent pipe components and terminations as well as both flex and rigid Comfort Glow vent com- ponents.

Your stove with burner system is approved to be vented either through the side wall, or vertically using the following guidelines:

Only use Comfort Glow or Simpson Dura- Vent GS venting components or kits spe- cifically approved for this stove and burner system.

Minimum clearance between vent pipes and combustible materials is 1" (25 mm), except where stated otherwise.

Screw

Do not recess venting terminals into a wall or siding.

Install horizontal venting with a 1/4" rise for every 12" of run toward the termination.

You may paint the vent terminal with 450ºF (232ºC) heat-resistant paint to co- ordinate with the exterior finish.

There must not be any obstruction such

as bushes, garden sheds, fences, decks, or utility buildings within 24" from the front of the termination cap.

Do not locate termination cap where ex- cessive snow or ice build up may occur. Be sure to clear vent termination area af- ter snow falls to prevent accidental block- age of venting system. When using snow blowers, do not direct snow towards vent termination area.

You must maintain minimum wall and ceiling clearances shown in Figures 3 and 4, pages 4 and 5.

LOCATION OF VENT

TERMINATION

When locating vent termination, it is impor- tant to observe the minimum clearances shown in Figure 18, page 9.

*Check with local codes or with the current CAN/CGA B149[.1 or .2] Installation Codes for Canada or the USA Installations follow the current National Fuel Gas Code, ANS Z223.1, also known as NFPA 54.

Firebox

Installed In Cast

Iron Stove Body

Figure 17 - Installing Rear Cover

8