![](/images/new-backgrounds/1294582/29458231x1.webp)
CF26PT
VENT-FREE PROPANE/LP BAY FRONT FIREPLACE
OPERATING
FIREPLACE
Continued
LIGHTING
INSTRUCTIONS
NOTICE: During initial operation of new heater, burning logs will give off a
1.STOP! Read the safety information on page 15.
2.Make sure equipment shutoff valve is fully open.
3. Turn control knob clockwise Clockwise to the OFF position.
4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation, page 15. If you don’t smell gas, go to the next step.
5.Turn control knob counterclockwise
C-clockwise
Press in control knob for five (5) sec- onds (see Figure 28).
Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.
•If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.
6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep press- ing ignitor button until pilot lights.
Note: If pilot does not stay lit, contact a qualified service person or gas sup- plier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.
7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
Note: If pilot goes out, repeat steps 3 through 7.This heater has a safety inter- lock system. Wait one (1) minute for sys- tem to reset before lighting pilot again.
8.Turn control knob counterclockwise
C-clockwise
CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.
Ignitor Button | Control Knob |
Figure 28 - Control Knob and Ignitor Button
Ignitor Electrode
Pilot Burner
Thermocouple
Figure 29 - Pilot
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
Turn control knob clockwise Clockwise to the OFF position.
Shutting Off Burners Only (pilot stays lit)
Turn control knob clockwise Clockwise to the PILOT position.
THERMOSTAT
CONTROL OPERATION
The thermostat control knob can be set to any comfort level between Hi and Lo. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.
Note: Selecting the Hi setting with the control knob will cause the burner to remain fully on, without modulating down in most cases.
MANUAL LIGHTING
PROCEDURE
1.Follow steps 1 through 5 under Light- ing Instructions, column 1.
2.Depress control knob and light pilot with match.
3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instruc- tions, column 1.
For more information, visit www.desatech.com | 16 | 107187 |