OWNER’S MANUAL

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after ODS/pilot is lit

1.

Burner orifice clogged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 17) or replace burner orifice

 

2.

Inlet gas pressure is too low

2.

Contact local propane/LP gas company

 

3.

Burner orifice diameter is too small

3.

Replace burner orifice

 

 

 

 

 

Delayed ignition burner

1.

Manifold pressure is too low

1.

Contact local propane/LP gas company

 

2.

Burner orifice clogged

2.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 17) or replace burner orifice

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 17) or replace burner orifice

 

2.

Damaged burner

2.

Replace damaged burner

 

3.

Gas regulator defective

3.

Replace gas control

 

 

 

 

 

Slight smoke or odor during initial operation

1.

Not enough air

1.

Check burner for dirt and debris. If

 

 

 

 

found, clean burner (see Cleaning and

 

 

 

 

Maintenance, page 17)

 

2.

Gas regulator defective

2.

Replace gas control

 

3.

Residues from manufacturing processes

3.

Problem will stop after a few hours of

 

 

and logs curing

 

operation

 

 

 

 

 

Moisture/condensation noticed on windows

1.

Not enough combustion/ventilation air

1.

Refer to Air for Combustion and Venti-

 

 

 

 

lation requirements (page 4)

 

 

 

 

 

Heater produces a whistling noise when

1.

Turning control knob to HI position

1.

Turn control knob to LO position and

burner is lit

 

when burner is cold

 

let warm up for a minute

 

2.

Air in gas line

2.

Operate burner until air is removed from

 

 

 

 

line. Have gas line checked by local pro-

 

 

 

 

pane/LP gas company

 

3.

Air passageways on heater blocked

3.

Observe minimum installation clear-

 

 

 

 

ances (see pages 7 through 9)

 

4.

Dirty or partially clogged burner orifice

4.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 17) or replace burner orifice

 

 

 

 

 

White powder residue forming within burner box or on adjacent walls or furniture

1.When heated, vapors from furniture pol- ish, wax, carpet cleaners, etc. may turn into white powder residue

1.Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

www.desatech.com

Continued

107187

19

For more information, visit www.desatech.com

Page 19
Image 19
Desa CF26PT installation manual Maintenance

CF26PT specifications

Desa CF26PT is a modern and efficient heating solution designed for residential and commercial spaces, providing comfort and convenience in various environments. This appliance stands out with its remarkable features that cater to diverse user needs.

One of the main features of the Desa CF26PT is its powerful heating capacity. With an output of up to 26,000 BTUs, it is capable of warming large areas quickly and effectively. This makes it an ideal choice for homes with open floor plans or larger spaces that require consistent warmth during colder months.

The technology integrated into the Desa CF26PT is another defining characteristic. The unit employs advanced heating technology, ensuring that it operates efficiently and reliably. This not only maximizes performance but also minimizes energy consumption, making it a cost-effective option for consumers. The inclusion of a multi-directional vent ensures that heat is distributed evenly throughout the space, eliminating cold spots and providing a comfortable environment.

In terms of design, the Desa CF26PT is compact and versatile, allowing it to fit seamlessly into various room styles. Its aesthetic appeal ensures that it complements existing décor while offering practical functionality. The unit is also designed for easy installation, with straightforward guidelines that allow users to set it up quickly without needing professional assistance.

Safety features are paramount in the design of the Desa CF26PT. It comes equipped with an automatic shut-off feature that activates in the event of overheating, ensuring peace of mind for users. Additionally, the unit incorporates a sturdy construction, making it durable and capable of withstanding the rigors of daily use.

User-friendly controls are another highlight of the Desa CF26PT. The intuitive interface allows users to adjust settings easily, ensuring personalized comfort. Whether it's choosing the desired temperature or setting up a timer, the functionality enhances the user experience, making it accessible for individuals of all ages.

In summary, the Desa CF26PT stands out as a reliable heating solution, offering power, efficiency, and safety in a stylish, compact design. Its advanced technology, user-friendly operation, and robust safety features make it a prominent choice for those seeking effective heating solutions in their spaces.