MANUAL LIGHTING PROCEDURE

OPERATING HEATER

Continued

22

MANUAL LIGHTING PROCEDURE

1.Remove lower front access panel on heater.

2.Locate pilot. Pilot is attached to the front of burner.

3.Follow steps 1 through 6 under Lighting Instructions, pages 20 and 21.

4.With control knob depressed, strike match. Hold match to pilot until pilot lights.

5.Follow steps 8 through 11 under Lighting Instructions, page 21.

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater

1.Fully depress control knob in any position other than PILOT to shut off burner and pilot.

2.If equipped, turn blower control to OFF position.

Shutting Off Burner Only (pilot stays lit)

1. Turn control knob to the PILOT position. At this setting, only the pilot remains lit.