Desa CGB35P, CGB50P installation manual Trouble- Shooting, Continued, see Checking Gas Con

Models: CGB35P CGB50P

1 40
Download 40 pages 41.98 Kb
Page 29
Image 29
(see Checking Gas Con-

TROUBLE- SHOOTING

Continued

WARNING

If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

OBSERVED

POSSIBLE

 

 

 

PROBLEM

CAUSE

 

REMEDY

 

 

 

 

 

 

Heater produces a

1.

Metal expanding

while

1.

This is common with

clicking/ticking noise

 

heating or contracting

 

most heaters. If noise is

just after burner is lit

 

while cooling.

 

 

excessive, contact quali-

or shut off.

 

 

 

 

fied service person.

 

 

 

 

 

 

Heater produces un-

1.

Heater burning

vapors

1.

Ventilate room. Stop us-

wanted odors.

 

from paint, hair

spray,

 

ing odor causing products

 

 

glues, etc.

 

 

while heater is running.

 

2.

Low fuel supply.

 

2.

Refill supply tank.

 

3.

Gas leak. See Warning

3.

Find and correct all leaks

 

 

statement at top of

 

(see Checking Gas Con-

 

 

page.

 

 

nections, page 13).

 

 

 

 

 

 

Heater shuts off in use. 1. Heater not venting correctly. Vent safety switch shuts off heater.

2. Low line pressure.

3. Pilot partially clogged.

1.Check venting system. If damaged or blocked, re- pair. If venting system is OK, have qualified ser- vice person replace vent safety switch, wire har- ness, or thermocouple in- terrupter.

2.Contact local propane gas company.

3.Clean pilot (see Cleaning and Maintenance, page 25).

Gas odor even when

1. Gas leak. See Warning

1.

Find and correct all leaks

control knob is in OFF

 

statement at top of

 

(see Checking Gas Con-

position.

 

page.

 

nections, page 13).

 

 

2.

Control valve damaged.

2.

Replace control valve.

 

 

 

 

 

 

Gas odor during com-

1. Foreign matter between

1.

Take apart gas tubing and

bustion.

 

control valve and burner.

 

remove foreign matter.

 

 

2.

Gas leak. See Warning

2.

Find and correct all leaks

 

 

 

statement at top of

 

(see Checking Gas Con-

 

 

 

page.

 

nections, page 13).

 

 

3.

Foreign fumes in area of

3.

Ventilate area around

 

 

 

heater being drawn

 

heater to remove any for-

 

 

 

through burner combus-

 

eign fumes.

 

 

 

tion.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29

 

 

 

 

 

 

 

 

100352

Page 29
Image 29