Desa CGB50P, CGB35P Inspecting Pilot And Burner Flame, Continued, Sharp Blue Flame, 100352

Models: CGB35P CGB50P

1 40
Download 40 pages 41.98 Kb
Page 24
Image 24
Sharp Blue

INSPECTING PILOT AND BURNER FLAME

Continued

24

Sharp Blue

Flame

Figure 20 - Correct Burner Flame Pattern

High

Yellow

Flame

Flame

Lifting

Off of

Burner

Figure 21 - Incorrect Burner Flame Patterns

If burner flame pattern is incorrect, as shown in Figure 21

turn heater off (see To Turn Off Gas to Appliance, page 22)

see Troubleshooting, pages 26 through 29.