Desa CGCDV36NR To Turn Off Gas, Manual Lighting Procedure, Optional Hand-Held Remote Operation

Models: (V)VC36P VC36N, VC36P, CGCDV36NR, CGCDV36PR CGCDV36NR

1 40
Download 40 pages 43.53 Kb
Page 24
Image 24
TO TURN OFF GAS

24

OPERATING FIREPLACE

Lighting Instructions (Cont.)

To Turn Off Gas To Appliance

Manual Lighting Procedure

Optional Hand-Held Remote Operation

OPERATING FIREPLACE

Continued

7.Turn gas control knob counterclockwise TO APPLIANCE to “PILOT”. (see Figure 44)

8.

Push in gas control knob all the way and hold. Immediately

 

light the pilot by repeatedly depressing the piezo spark

 

ignitor until a flame appears. Continue to hold for about

 

one (1) minute after the pilot is lit. Release gas control knob

 

and it will pop back. Pilot should remain lit. If it goes out,

 

repeat steps 5 through 8.

 

 

If gas control knob does not pop up when released, stop and

 

immediately call your service technician or gas supplier.

 

If the pilot will not stay lit after several tries, turn the gas

 

 

control knob to “OFF” and call your service technician

 

 

or gas supplier.

 

9.

Turn on all electric power to the fireplace.

to “ON”.

10.

Turn gas control knob counterclockwise

11.

This valve is equipped with a HI/LO feature. Set fireplace

 

input as desired.

 

12. Close lower louver panel.

 

Gas Control

 

 

Variable Control Knob

 

 

 

 

 

Knob

 

 

 

Piezo

 

IL

 

 

Ignitor

O

OT

O

 

 

P

IH

 

F

F

 

 

 

 

 

 

N

 

 

 

 

LO

Figure 44 - Control Valve

 

 

 

 

TO TURN OFF GAS

 

TO APPLIANCE

1.Open lower louver panel.

MANUAL LIGHTING

PROCEDURE

1.Remove glass door (see Removing/Replacing Glass Door, page 21).

2.Follow steps 1 through 8 under Lighting Instructions, page 23.

3.Depress gas control knob and light pilot with match.

4.Keep gas control knob pressed in for 30 seconds after light- ing pilot. After 30 seconds, release gas control knob. Follow steps 10 through 14 under Lighting Instructions, page 23.

5.Replace glass door (see Removing/Replacing Glass Door, page 21).

OPTIONAL HAND-HELD

REMOTE OPERATION

Note: All remote control accessories must be purchased sepa- rately (see Accessories, page 36). Follow instructions included with the remote control.

NOTICE: You must light the pilot before using the hand-held remote control unit. See Lighting Instruc- tions, page 23.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 45). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

2.

Set selector switch in the OFF position to prevent draining

 

battery.

3.Turn off all electrical power to the appliance if service is to be performed.

4.Push in gas control knob slightly and turn clockwise MANUAL LIGHTING to “OFF”.

5.Close lower louver panel.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing

Blower Control Knob

(Optional Accessory)

OFF

ON

Selector Switch

ON OFF REMOTE

in Remote

 

Position

 

 

 

Variable

 

 

 

Control Knob

N

 

 

O

 

L

 

 

 

 

T

 

O

I

L

 

O

H

O

 

 

 

I

F

 

 

P F

 

Gas Control Knob

in ON Position

 

one of the following:

 

1.

Turn gas control knob clockwise

to the PILOT position.

2.Set selector switch in the OFF position.

Figure 45 - Setting the Selector Switch, Gas Control Knob and Variable Control Knob for Remote Operation

www.desatech.com

116200-01C

Page 24
Image 24
Desa CGCDV36NR To Turn Off Gas, Manual Lighting Procedure, Optional Hand-Held Remote Operation, To Appliance, Continued