Desa CGCDV42NR, CGCDV42PR, VC42N, VC42P Model BKT Installation, Blower Model BKT

Models: CGCDV42NR, CGCDV42PR, VC42N, VC42P VC42N VC42P

1 44
Download 44 pages 48 Kb
Page 20
Image 20

Fireplace

Installation

Continued

CAUTION: Never touch the blower wheel while in operation.

9.Check to make sure that the power cord is com- pletely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation. Turn blower off by turning knob fully counterclock- wise before continuing.

10.Peel off the backing paper and stick the sup- plied wiring diagram decal on the firebox bot- tom approximately 12" in front of the blower (see Figure 28).

Wiring Diagram Decal

12" in Front of Blower

Figure 28 - Location of Wiring Diagram Decal (Model May Vary From Illustration)

Model BKT Installation

Note: When installing the BKT thermostati- cally-controlled blower, you must first secure the thermal switch bracket to the blower if it has not already been factory installed.

1.Place the green ground wire with ring terminal between the bottom hole on the thermal switch bracket and the top ear hole on the blower as- sembly. Insert the phillips screw into all three pieces and tighten securely (see Figure 29).

2.Connect wire harness and power cord ter- minals. Connect the blue jumper wire to the blower motor terminal and the right side ter- minal of the thermal switch. Connect the black wire to the left side of the thermal switch and the white wire to the other remaining blower motor terminal.

Note: The power cord outer insulation sleeve may have to be stripped slightly to allow enough wire length to reach and make all connections. DO NOT trim excessive length away. Just enable enough to make all connections securely.

3.Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward and the thermodisc positioned up near the fireplace bottom. The thermodisc must be oriented near the fireplace bottom as shown in Figure 29 in order to sense tempera- ture and properly operate. The blower will be held in position against the back wall by the magnets incorporated onto the blower housing (see Figure 29).

4.Be certain that all wire terminals are securely at- tached to terminals on blower motor and thermal switch and that the screw for the thermodisc bracket and green ground wire is tight.

5.Mount the speed control box against the mounting plate provided in the lower fireplace cavity by placing the plastic control shaft forward through the round hole (see Figure 27, page 19).

6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against mounting plate. Place control knob provided on shaft (see Figure 27, page 19).

Power Cord

 

Thermal

White Wire Blue Wire

 

Magnetic

Switch

 

 

Strips

Bracket

 

 

 

Black

 

Air Flow

 

Direction

Wire

 

 

Phillips

 

Ring Terminal on

Screw Thermal

Green Wire

Switch

 

Air Flow

Direction

Thermodisc

 

Route BKT Blower

Blower

Magnets

Through This Area

Location

Side View Firebox Bottom

Figure 29 - Blower Model BKT

20

www.desatech.com

116236-01F

Page 20
Image 20
Desa CGCDV42NR, CGCDV42PR, VC42N, VC42P installation manual Model BKT Installation, Blower Model BKT

CGCDV42NR, CGCDV42PR, VC42N, VC42P, VC42N, VC42P specifications

Desa offers a variety of versatile gas fireplaces, notably the VC42P, VC42N, CGCDV42NR, CGCDV42PR, and VC42N model lines. These fireplaces are designed to enhance home comfort and aesthetic appeal, marrying efficient heating technology with elegant design.

The VC42P and VC42N models are known for their powerful heating capabilities and stylish appearances. The ‘P’ in VC42P refers to its propane fuel option, ideal for homes not connected to natural gas lines. In contrast, the VC42N operates on natural gas, ensuring flexibility for homeowners based on their local fuel availability. Both models feature advanced flame technology, which creates a realistic fire experience, enhancing the ambiance of any space.

The CGCDV42NR and CGCDV42PR models take utility and design a step further. The ‘CG’ signifies these are contemporary gas fireplaces that come with a range of customizable options, including different face designs and finishes that can seamlessly fit into any modern home décor. Both the NR (natural gas) and PR (propane) versions showcase high efficiency, providing powerful heat alongside lower emissions, making them environmentally conscious choices.

All these models are equipped with modern ignition systems that ensure user-friendly operation. For instance, the featured electronic ignition provides reliable and quick startup, while safety components like flame sensors guarantee peace of mind during use. Additionally, these fireplaces offer remote control capabilities for added convenience.

Another notable characteristic is the option for ceramic glass fronts, which are not only aesthetically pleasing but also enhance heat efficiency, allowing space to warm up quickly. With different logs and decorative media options, users can create their ideal fireplace ambiance, customizing the interior look to match personal preferences.

In summary, the Desa VC42P, VC42N, CGCDV42NR, and CGCDV42PR models exemplify a harmonious blend of design, technology, and functionality. These fireplaces are not just heat sources; they are statement pieces that elevate living spaces while providing convenient heating solutions that cater to modern lifestyles. Whether using natural gas or propane, these units stand out with their reliability, efficiency, and aesthetic options, making them a popular choice for homeowners looking to enhance their comfort and home value.