Venting Installation

Instructions

NOTICE: Read these instruc- tions completely before at- tempting installation.

These models are tested and approved for use with DESA (direct-vent) pipe components and terminations.

The venting system must terminate on the outside of the structure and can not be attached to a chimney or flue system serving a separate solid fuel or gas burning appliance. A direct-vent appliance must have its own venting system. DO NOT common vent this appliance.

These models are approved to be vented either horizontally through an outside wall or vertically through a roof or chase enclosure using the fol- lowing guidelines:

When venting system terminates horizontally on an outside wall, you may install a standoff if the termination cap is to be installed directly on a combustible finish such as vinyl, wood, stucco, etc.

Never run the vent downward as this may cause excessive temperatures which could cause a fire.

Vent pipe air space clearances to combustibles are 1" on all sides except on the horizontal sections, which requires 2" clearance from the top of the pipe. Where the termination cap penetrates a combustible wall, 1" air space clearance is required.

Snorkel terminations are required when minimum clearance to grade cannot be met (see Figure 16 on page 13).

Have fireplace and selected vent components on hand to help determine the exact measurements when elbowing or offsetting. Always use wall firestops when penetrating walls and firestops when penetrating ceilings or attic spaces.

Install horizontal venting with a 1/4" rise for every 12" of run toward the termination.

For installation of fireplace at elevations of 4000 feet or greater, pay special attention to venting requirement recommendations.

WARNING: Read all instruc- tions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life.

NOTICE:Failuretofollowthesein- structions will void the warranty.

NOTICE: Do not seal termination cap to vent pipe. Cap must be removable for vent inspection and maintenance.

Installation Precautions

Wear gloves and safety glasses for protection

Use extreme caution when using ladders or when on roof tops

Be aware of electrical wiring locations in walls and ceilings

The following actions will void the warranty on your venting system:

Installation of any damaged venting component

Unauthorized modification of the venting sys- tem (Do not cut or alter vent components)

Installation of any component part not manu- factured or approved by DESA

Installation other than as instructed by these instructions

WARNING: This gas fireplace andventassemblymustbevented directlytotheoutside.Theventing system must NEVER be attached to a chimney serving a separate solidfuelburningappliance.Each direct-vent gas appliance must useaseparateventsystem.Donot use common vent systems.

WARNING: Vent pipe air spaceclearancestocombustibles are 1" on all sides except on the horizontalsections,whichrequire 2" clearances from the top of the pipe. Where the termination cap penetrates a combustible wall, 1" air space clearance is required.

116236-01Fwww.desatech.com

Page 9
Image 9
Desa CGCDV42NR, CGCDV42PR, VC42N, VC42P Venting Installation Instructions, Installation Precautions

CGCDV42NR, CGCDV42PR, VC42N, VC42P, VC42N, VC42P specifications

Desa offers a variety of versatile gas fireplaces, notably the VC42P, VC42N, CGCDV42NR, CGCDV42PR, and VC42N model lines. These fireplaces are designed to enhance home comfort and aesthetic appeal, marrying efficient heating technology with elegant design.

The VC42P and VC42N models are known for their powerful heating capabilities and stylish appearances. The ‘P’ in VC42P refers to its propane fuel option, ideal for homes not connected to natural gas lines. In contrast, the VC42N operates on natural gas, ensuring flexibility for homeowners based on their local fuel availability. Both models feature advanced flame technology, which creates a realistic fire experience, enhancing the ambiance of any space.

The CGCDV42NR and CGCDV42PR models take utility and design a step further. The ‘CG’ signifies these are contemporary gas fireplaces that come with a range of customizable options, including different face designs and finishes that can seamlessly fit into any modern home décor. Both the NR (natural gas) and PR (propane) versions showcase high efficiency, providing powerful heat alongside lower emissions, making them environmentally conscious choices.

All these models are equipped with modern ignition systems that ensure user-friendly operation. For instance, the featured electronic ignition provides reliable and quick startup, while safety components like flame sensors guarantee peace of mind during use. Additionally, these fireplaces offer remote control capabilities for added convenience.

Another notable characteristic is the option for ceramic glass fronts, which are not only aesthetically pleasing but also enhance heat efficiency, allowing space to warm up quickly. With different logs and decorative media options, users can create their ideal fireplace ambiance, customizing the interior look to match personal preferences.

In summary, the Desa VC42P, VC42N, CGCDV42NR, and CGCDV42PR models exemplify a harmonious blend of design, technology, and functionality. These fireplaces are not just heat sources; they are statement pieces that elevate living spaces while providing convenient heating solutions that cater to modern lifestyles. Whether using natural gas or propane, these units stand out with their reliability, efficiency, and aesthetic options, making them a popular choice for homeowners looking to enhance their comfort and home value.