CONNECTING TO GAS SUPPLY
Continued
Approved
Flexible
Gas Line
3" Minimum
A.G.A.
Manual Shutoff Valve
With 1/8" NPT Tap*
From External Regulator
(11" W.C. to 14" W.C.
Pressure)
Sediment
Tee Joint
Trap
Figure 17 - Gas Connection
Pipe Nipple
Cap
*Purchase the optional A.G.A.
CONNECTING FIREPLACE TO GAS SUPPLY
Installation Items Needed
•Phillips screwdriver
•sealant (resistant to propane gas, not provided)
1.Remove fireplace screen. Remove two screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove.
2.Remove screws that attach branch support to fireplace (see Figure 18). Care- fully lift up branch support and remove from fireplace (see Figure 18).
Branch | Screen Shipping |
Support | Screw |
| Shoulder Screw |
Screen | Flexible Gas Line |
|
Figure 18 - Removing Log Base Assembly From Fireplace
3.Route flexible gas line from manual shutoff valve into fireplace through side or rear access holes in outer casing. Route flexible gas supply line through fireplace access holes in outer casing.
NOTICE
Most building codes do not permit concealed gas connections. A flexible gas line is provided to allow accessibility from the fireplace. The flexible gas supply line connection to the manual shutoff valve should be accessible.
17
103667