Desa CGCF26TP Trouble- Shooting, Continued, Connections, page, Cleaning and Mainte

Models: CGCF26TP

1 36
Download 36 pages 34.01 Kb
Page 28
Image 28
Connections, page 18)

28

TROUBLE- SHOOTING

Continued

WARNING

WARNING ICON

G 001

If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Clean- ing supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

 

OBSERVED

POSSIBLE

 

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

 

 

Fireplace produces a

1.

Metal expanding while

1.

This is common with

 

clicking/ticking noise

 

heating or contracting

 

most fireplaces. If noise

 

just after burner is lit

 

while cooling

 

is excessive, contact

 

or shut off

 

 

 

qualified service person

 

 

 

 

 

 

 

Fireplace produces

1.

Fireplace burning vapors

1.

Ventilate room. Stop

 

unwanted odors

 

from paint, hair spray,

 

using odor causing

 

 

 

glues, etc. (See IMPOR-

 

products while fire-

 

 

 

TANT statement above)

 

place is running

 

 

2.

Low fuel supply

2.

Refill supply tank

 

 

3.

Gas leak. See Warn-

3.

Locate and correct all

 

 

 

ing statement at

 

leaks (see Checking Gas

 

 

 

top of page

 

Connections, page 18)

 

 

 

 

 

 

 

Fireplace shuts off in

1.

Not enough fresh air is

1.

Open window and/or

 

use (ODS operates)

 

available

 

door for ventilation

 

 

2.

Low line pressure

2.

Contact local propane/

 

 

 

 

 

LP gas company

 

 

3.

ODS/pilot is partially

3.

Clean ODS/pilot (see

 

 

 

clogged

 

Cleaning and Mainte-

 

 

 

 

 

nance, page 25)

 

 

 

 

 

 

 

Gas odor even when

1.

Gas leak. See Warn-

1.

Locate and correct all

 

control knob is in

 

ing statement at

 

leaks (see Checking Gas

 

OFF position

 

top of page

 

Connections, page 18)

 

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

 

 

Gas odor during

1.

Foreign matter be-

1.

Take apart gas tubing

 

combustion

 

tween control valve

 

and remove foreign

 

 

 

and burner

 

matter

 

 

2.

Gas leak. See Warn-

2.

Locate and correct all

 

 

 

ing statement at

 

leaks (see Checking Gas

 

 

 

top of page

 

Connections, page 18)

 

 

 

 

 

 

Moisture/condensa-

1.

Not enough combus-

1. Refer to Air for Combus-

 

tion noticed on

 

tion/ventilation air.

 

tion and Ventilation re-

 

windows

 

 

 

quirements

 

 

 

 

 

(page 6)

103667

Page 28
Image 28
Desa CGCF26TP installation manual Trouble- Shooting, Continued, Connections, page, Cleaning and Mainte