Desa CGCF26TP installation manual Inspecting Burner, Continued, Burner Flame Pattern

Models: CGCF26TP

1 36
Download 36 pages 34.01 Kb
Page 24
Image 24
BURNER FLAME PATTERN

INSPECTING BURNER

Continued

24

BURNER FLAME PATTERN

Figure 26 shows a correct burner flame pattern. Figure 27 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than one inch above the log.

Note: When using the fireplace the first time, the flame will be yellow for approxi- mately one hour until the log cures.

WARNING

WARNING ICON

G 001

If yellow tipping occurs, your fireplace could produce increased levels of carbon monoxide. If burner flame pattern shows yellow tipping, follow instructions at bottom of this page.

NOTICE

Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the fireplace and burn causing brief patches of orange flame.

Top of

Flame

About One

Inch Above

Logs

CORRECT FLAME PATTERN

AT HIGH POSITION

Figure 26 - Correct Burner Flame Pattern

Yellow

Tipping

INCORRECT FLAME PATTERN

AT HIGH POSITION

Figure 27 - Incorrect Burner Flame Pattern

If burner flame pattern is incorrect, as shown in Figure 27

turn fireplace off (see To Turn Off Gas to Appliance, page 22).

see Troubleshooting, pages 25 through 28.

103667

Page 24
Image 24
Desa CGCF26TP Inspecting Burner, Continued, Burner Flame Pattern, Correct Flame Pattern At High Position