CHECKING GAS

OWNER’S MANUAL

INSTALLATION

Continued

A.G.A. Design-Certified

Manual Shutoff Valve

With 1/8" NPT Tap*

 

From

 

External

Approved

Regulator

(11" W.C.

Flexible

to 14"

Gas Line

W.C.

 

Pressure)

3" Minimum

 

Pipe Nipple Cap

Tee Joint

Sediment Trap

Figure 31 - Gas Connection

*Purchase the optional A.G.A. design-cer- tified manual shutoff valve from your dealer. See Accessories, page 32.

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed

5/16" hex socket wrench or nut-driver

Phillips screwdriver

sealant (resistant to propane/LP gas, not provided)

1.Remove fireplace screen. Remove two screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove.

2.Remove screws that attach log base assembly to fireplace. Carefully lift up log base assembly and remove from fireplace (see Figure 32).

Pressure Testing Gas Supply Piping System CAUTION: Do not pick up log base assembly by burners. This could damage burners. Only handle base by grates.

3. Route flexible gas line (provided by

installer) from manual shutoff valve to

fireplace. Route flexible gas supply line

Figure 32 - Removing Log Base Assem- bly From Fireplace

NOTICE : Most building codes do not permit concealed gas con- nections. A flexible gas line is provided to allow accessibility from the fireplace. The flexible gas supply line connection to the manual shutoff valve should be accessible.

4. Attach a 45˚ flare union gas connector to flexible gas line from gas supply (see Figure 33). Connect flare union to flex- ible gas line attached to gas regulator of fireplace (see Figure 33).

5. Check all gas connections for leaks. See Checking Gas Connections, column 3.

6. Replace log base assembly back into fireplace. Feed flexible gas line into fireplace base area while replacing log base assembly. Make sure the entire flexible gas line is in fireplace base area. Reattach log base assembly to fireplace with screws removed in step 2.

 

Flexible Gas Line from

 

Manual Shutoff Valve

To Fireplace

Provided by Installer

Gas Regulator

Gas

Manual

Connector

Shutoff

 

 

Valve

Flexible Gas Line from

Fireplace Gas Regulator

To

External

Provided with Fireplace

Regulator

 

CHECKING GAS

CONNECTIONS

Manual background WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once.

Manual backgroundWARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG

1.Disconnect fireplace and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage fireplace gas regulator.

2.Cap off open end of gas pipe where manual shutoff valve was connected.

3.Pressurize supply piping system by ei- ther using compressed air or opening propane supply tank valve.

4.Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

5.Correct all leaks at once.

6.Reconnect fireplace and manual shutoff valve to gas supply. Check reconnected fittings for leaks.

through one of the access holes.

Figure 33 - Attaching Flexible Gas Lines

 

Together

Continued

103414

15

Page 15
Image 15
Desa CGFP28PT installation manual Checking Gas Connections, Pressure Testing Gas Supply Piping System