CGFP28P and CGFP28PT
UNVENTED PROPANE/LP GAS FIREPLACE
INSTALLATION
Continued
Test Pressures Equal To or Less Than 1/2 PSIG
1.Close manual shutoff valve (see Fig- ure 34).
2.Pressurize supply piping system by ei- ther using compressed air or opening propane supply tank valve.
3.Check all joints from propane supply tank to manual shutoff valve (see Fig- ure 35). Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.
4.Correct all leaks at once.
Pressure Testing Fireplace Gas Connections
1.Open manual shutoff valve (see Fig- ure 34).
2.Open propane supply tank valve.
3.Make sure control knob of fireplace is in the OFF position.
4.Check all joints from manual shutoff valve to thermostat gas valve (see Fig- ure 35). Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.
5.Correct all leaks at once.
6.Light fireplace (see Operating Fire- place, pages 18 and 19 [Thermostat- controlled models] or pages 19 and 20
7.Turn off fireplace (see To Turn Off Gas to Appliance, page 18, [Thermostat- controlled models] or page 20 [Manu-
Open
Manual
Shutoff
Valve
Closed
Manual Shutoff Valve
Propane
Supply
Tank
Manual Gas Valve
Figure 35 - Checking Gas Joints
Figure 34 - Manual Shutoff Valve
16 | 103414 |