UNVENTED NATURAL GAS LOG HEATER
SPECIFICATIONS
Model | CGG3324NT | CGG2618N | CGG3324N | CGG3630N |
Btu (Variable) | 20,000/33,000 | 16,000/26,000 | 20,000/33,000 | 21,500/36,000 |
Type Gas | Natural Gas Only | Natural Gas Only | Natural Gas Only | Natural Gas Only |
Ignition | Piezo | Piezo | Piezo | Piezo |
Pressure | 3.4" W.C. | 3.4" W.C. | 3.4" W.C. | 3.4" W.C. |
Inlet Gas Pressure (in. of water) |
|
|
|
|
Maximum | 10.5" | 10.5" | 10.5" | 10.5" |
Minimum* | 5" | 5" | 5" | 5" |
* For purpose of input adjustment |
|
|
| |
Shipping Weight | 38 lbs. | 36 lbs. | 38 lbs. | 40 lbs. |
ACCESSORIES
Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA International’s Parts Department at
MANUAL SHUTOFF VALVE GA5010
For all models. Manual shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.
DAMPER CLAMP - GA6080 (Not Shown)
For variably controlled models. Permanently opens chimney flue damper for vented op- eration.
LAVA ROCK - GA6060 (Not Shown)
For all models. Order when additional rock is desired. (3 lb. bag)
TECHNICAL
SERVICE
You may have further questions about in- stallation, operation, or troubleshooting.
If so, contact DESA International’s Techni- cal Service Department at
You can also visit DESA International’s Technical Service web site at
www.desatech.com.
SERVICE HINTS
When Gas Pressure Is Too Low
•pilot will not stay lit
•burners will have delayed ignition
•heater will not produce specified heat
When Gas Quality Is Bad
•pilot will not stay lit
•burners will produce flames and soot
•heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.
FIREPLACE HOOD
Black - GA6050
Brass - GA6052
Antique Brass - GA6053
For all models. Helps deflect heat away from mantel or wall above fireplace.