UNVENTED (VENT-FREE) GAS LOG HEATER

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

One or both burners do not light after ODS/

1.

Burner orifice(s) clogged

1.

Clean burner(s) (see Cleaning and

pilot is lit

 

 

 

Maintenance, page 18) or replace

 

 

 

 

burner orifice(s)

 

2.

Inlet gas pressure is too low

2.

Contact local propane/LP gas company

 

3.

Mislocated crossover tube

3.

Contact qualified service person

 

4.

Burner orifice(s) diameter is too small

4.

Replace burner orifice(s)

 

 

 

 

 

Delayed ignition of one or both burners

1.

Manifold pressure is too low

1.

Contact local propane/LP gas company

 

2.

Burner orifice(s) clogged

2.

Clean burner(s) (see Cleaning and

 

 

 

 

Maintenance, page 18) or replace

 

 

 

 

burner orifice(s)

 

3.

Mislocated crossover tube

3.

Contact qualified service person

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 18) or replace burner orifice

 

2.

Damaged burner

2.

Replace damaged burner

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

Yellow flame in front burner during burner

1.

Not enough air

1.

Check burner(s) for dirt and debris. If

combustion

 

 

 

found, clean burner(s) (see Cleaning

 

 

 

 

and Maintenance, page 18)

 

2.

Gas regulator defective

2.

Replace gas regulator

 

 

 

 

 

Slight smoke or odor during initial operation 1. Residues from manufacturing processes and logs curing

1.Problem will stop after a few hours of operation

Moisture/condensation noticed on windows

1.

Not enough combustion/ventilation air

1.

Refer to Air for Combustion and Venti-

 

 

 

 

lation requirements (page 4)

 

 

 

 

 

Heater produces a whistling noise when

1.

Turning control knob to HI position

1.

Turn control knob to LO position and

burners are lit

 

when burners are cold

 

let warm up for a minute

 

2.

Air in gas line

2.

Operate burners until air is removed

 

 

 

 

from line. Have gas line checked by lo-

 

 

 

 

cal propane/LP gas company

 

3.

Air passageways on heater blocked

3.

Observe minimum installation clear-

 

 

 

 

ances (see pages 7 through 9)

 

4.

Dirty or partially clogged burner

4.

Clean burners (see Cleaning and Main-

 

 

orifice(s)

 

tenance, page 18) or replace burner

 

 

 

 

orifice(s)

White powder residue forming within burner box or on adjacent walls or furniture

1.When heated, vapors from furniture pol- ish, wax, carpet cleaners, etc. turn into white powder residue

1.Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

www.desatech.com

20

103425

Page 20
Image 20
Desa CGG2618P, CGG3630P, CGG3324P(T) Unvented Vent-Freegas Log Heater, Troubleshooting, Continued, and Maintenance, page

FAQ

What are the possible causes for delayed ignition of the burners?

Possible causes may include low manifold pressure, clogged burner orifices, and mislocated crossover tube. Contact your local propane/LP gas company or a qualified service person for assistance.

Why is there a yellow flame in the front burner during combustion?

The yellow flame may be due to insufficient air. Check the burners for dirt and debris, and clean them as needed. Additionally, consider replacing the gas regulator if necessary.

How can I prevent the formation of white powder residue within the burner box or on adjacent walls or furniture?

Turn off the heater when using furniture polish, wax, carpet cleaners, or similar products to prevent the formation of white powder residue.