OWNER’S MANUAL
OPERATING
HEATER
Continued
4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation, page 16. If you don’t smell gas, go to the next step.
5.Press in control knob and turn counter-
clockwise C-clockwise
•If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.
Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.
6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing igni- tor button until pilot lights.
Note: If pilot does not light, contact a qualified service person or gas sup- plier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.
7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
Note: If pilot goes out, repeat steps 3 through 7.
8.Push in and turn control knob coun-
terclockwise C-clockwise
Ignitor Electrode
Thermocouple
Pilot Burner
Figure 24 - Pilot
VARIABLE CONTROL
OPERATION
The variable control valve can be set to any heat setting and flame height desired between high and low by simply turning the control knob until that setting is at- tained. Even the lowest setting provides realistic flames and glowing embers from two burners. Selecting higher settings pro- duces greater heat output. This results in increased heating comfort.
WARNING: Do not operate heater between pilot and high.
CAUTION: Do not try to adjust heating levels by using the manual shutoff valve.
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1.Press in and turn control knob clock-
wise Clockwise to the HIGH position.
2.Turn the control knob clockwise Clockwise to the PILOT position.
3.Press in control knob and turn clock-
wise Clockwise to the OFF Position.
Shutting Off Burners Only (pilot stays lit)
1.Turn the control knob clockwise Clockwise to the HIGH position.
2.Press in and turn control knob clock-
wise Clockwise to the pilot position.
MANUAL LIGHTING
PROCEDURE
1.Follow steps 1 through 5 under Light- ing Instructions, page 16.
2.Depress control knob and light pilot with match.
3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, column 1.
INSPECTING
BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 25 shows a correct pilot flame pattern. Figure 26 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple. This will cause the thermocouple to cool. When the thermo- couple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in Figure 26
•turn heater off (see To Turn Off Gas to Appliance, page 16
•seeTroubleshooting, pages 19 through 21
Thermocouple | Pilot Burner |
Figure 25 - Correct Pilot Flame Pattern
Thermocouple
Pilot Burner
Figure 26 - Incorrect Pilot Flame Pattern
Continued