Desa CGG3324P(T), CGG3630P, CGG2618P Unvented Vent-Freegas Log Heater, Operating Heater, Continued

Models: CGG2618P CGG3324P(T) CGG3630P

1 30
Download 30 pages 44.49 Kb
Page 16
Image 16
TO TURN OFF GAS

UNVENTED (VENT-FREE) GAS LOG HEATER

OPERATING

HEATER

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise Shutting Off Heater to the OFF position.

Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise Shutting Off Burners Only (pilot stays lit) to the PILOT position.

THERMOSTAT

CONTROL OPERATION

(Thermostat-Controlled

Models Only)

The thermostat control knob can be set to any comfort level between Hi and Lo. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

Note: Selecting the Hi setting with the control knob will cause the burners to remain fully on, without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Light- ing Instructions, page 15.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, page 15.

Variable Manually-Controlled Models

FOR YOUR

SAFETY READ

BEFORE LIGHTING

THERMOSTAT WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When light- ing the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un- der water.

LIGHTING

INSTRUCTIONS

(Thermostat-Controlled WARNING:

If fireplace has glass doors, never operate this heater with glass doors closed. If you oper- ate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the High heat setting but will find the heat output excessive. You can open the chim- ney damper (if you have one) fully or partially to release some of the heat.

MANUAL LIGHTING WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information column 2.

2.Make sure manual shutoff valve is fully open.

3.Press in and turn control knob clock-

wise

Clockwise

to the OFF

position.

 

 

 

 

HIPILOT

 

OFF

 

LO

Ignitor Button

Control Knob

Figure 23 - Control Knob and Ignitor Button Location

16

103425

Page 16
Image 16
Desa CGG3324P(T), CGG3630P Unvented Vent-Freegas Log Heater, Operating Heater, Continued, To Turn Off Gas To Appliance

FAQ

How do I turn off the gas to the heater?

To turn off the gas to the heater, simply turn the control knob clockwise to the OFF position.

What should I do if I smell gas around the heater?

If you smell gas around the heater, do not try to light any appliance. Instead, immediately call your gas supplier from a neighbor's phone and follow their instructions.

Should I operate the heater with the fireplace doors closed?

No, if the fireplace has glass doors, never operate the heater with the doors closed, as heat buildup inside the fireplace can cause the glass to burst.