Desa CGN10RL Inspecting Burner, To Turn Off Gas To Appliance, Manual Lighting Procedure

Models: CGN10RL

1 20
Download 20 pages 63.33 Kb
Page 11
Image 11
INSPECTING

OWNER’S MANUAL

OPERATING

HEATER

Continued

Control

KnobsBurners

TO TURN OFF GAS OFF Shutting Off Heater

PILOT

LOW

Shutting Off Burner Only (pilot stays lit) OFF MANUAL LIGHTING

PILOT

HIGH

Manual background OFF Manual background

4.

Keep control knob pressed in for 10

BURNER FLAME PATTERN

 

seconds after pilot is lit. After 10

Figure 20 shows a correct burner flame

 

seconds, release control knob.

 

pattern. Figure 21 shows an incorrect burner

5.

Replace front panel.

flame pattern.

 

 

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 18 shows a correct pilot flame pat- tern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the

thermocouple cools, the heater will shut Figure 20 - Correct Burner Flame Pattern down.

Pilot Burner

Thermocouple

Figure 17 - Burner Patterns

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

Shutting Off Burner Only (pilot stays lit)

1.Turn control knob clockwise to the PILOT position.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 10, page 7).

2.Follow steps 1 through 5 under Lighting Instructions, page 10.

3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

GOOD PILOT

GRH/OV 009

Figure 18 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

BAD PILOT/LP

GRH/OV 008

Figure 19 - Incorrect Pilot Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 19

turn heater off (see To Turn Off Gas to Appliance).

see Troubleshooting, pages 12 through 14.

Figure 21 - Incorrect Burner Flame Pat- tern

If burner flame pattern is incorrect, as shown in Figure 21

turn heater off (see To Turn Off Gas to Appliance).

see Troubleshooting, pages 12 through 14.

103549

11

Page 11
Image 11