OWNER’S MANUAL

INSTALLING

TO WALL

Continued

INSTALLING HEATER TO WALL

Marking Screw Locations

1.Determine where you will locate heater.

WARNING: Maintain minimum clearances shown in Figure 5. If you can, provide greater clear- ances from floor and joining wall.

2.Mark two mounting screw locations on wall (see Figure 5).

Attaching to Wall Anchor Method

Follow instructions below to attach mount- ing screws to hollow walls (wall areas be- tween studs) or solid walls (concrete or masonry).

1.Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1 1/4" deep.

2.Fold wall anchor (see Figure 6).

3.Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

Placing Heater on Mounting Screws

1.Locate two keyhole slots on back panel of heater (see Figure 9).

2.Place large openings of slots over screwheads. Slide heater down until screws are in small portion of slots.

Keyhole

Slots

Figure 9 - Location Of Keyhole Slots On Back Panel Of Heater

Removing Front Panel of Heater

 

 

10 7/8"

 

 

7 3/4"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum To

 

 

 

 

 

 

 

 

Maintain 6"

 

 

 

 

 

 

 

 

Clearance

 

 

 

 

 

 

 

 

From Wall

Mounting

 

 

 

 

 

WALL

 

 

 

Screw

 

 

 

 

 

 

 

 

 

 

Locations

20 1/4"

JOINING

 

 

Minimum To

 

 

 

Maintain 3"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clearance

 

 

 

 

 

 

 

 

From Floor

FLOOR

Figure 5 - Mounting Screw Locations

Installing Two Mounting Screws

Note: Wall anchors and mounting screws are in hardware package. The hardware pack- age is provided with heater.

Attaching to Wall Stud Method

For attaching mounting screw to wall stud

1.Drill hole at marked location using 9/ 64" drill bit.

2.Insert mounting screw into wall stud.

3.Tighten screw until 1/16" space (thickness of penny) is between

screwhead and wall.

Figure 6 - Folding Anchor

4.For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings (see Figure 7). IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings.

Thin Walls

(1/4" to 1/2" thick)

Figure 7 - Popping Open Anchor Wings For Thin Walls

5.Tighten two screws until 1/16" space (thickness of penny) is between screwheads and wall (see Figure 8).

Thin or Thick Wall

(thick wall shown)

1/16" Space

Solid

Wall

Figure 8 - Tightening Anchors

1.Remove two screws near bottom corners of front panel.

2.Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4".

3.Pull bottom of front panel forward, then down.

Figure 10 - Removing Front Panel Of Heater

Installing Bottom Mounting Screw

1.Locate bottom mounting hole. This hole is near bottom on back panel of heater (see Figure 11, page 8).

2.Mark screw location on wall.

3.Remove heater from wall.

Continued

103549

7

Page 7
Image 7
Desa CGN10RL installation manual Installing Heater to Wall

CGN10RL specifications

Desa CGN10RL is a state-of-the-art gas-powered generator designed for both residential and commercial applications, offering reliability and efficiency. With a robust 10,000-watt peak output and a continuous output of 8,000 watts, this generator ensures that users can power essential appliances and tools with ease, making it an ideal choice for home emergency power, outdoor activities, and job sites.

One of the main features of the Desa CGN10RL is its powerful engine, which is designed for durability and long life. The generator utilizes a 420cc engine that is specifically engineered to provide high performance under various conditions. This engine is equipped with an automatic voltage regulator that ensures stable output, protecting connected devices from voltage fluctuations. The recoil start system provides quick and reliable starting, even in cold weather.

The CGN10RL incorporates advanced noise reduction technologies, allowing for quieter operation compared to standard generators. This is particularly beneficial in residential areas or during nighttime use, where noise levels can be a concern. The design includes a soundproofing casing that minimizes noise output while maintaining excellent ventilation for cooling.

In terms of fuel efficiency, the Desa CGN10RL has a large fuel tank capacity of 7 gallons, which provides extended run times of up to 12 hours at half load. This means less frequent refueling, which is a significant advantage for users who need sustained power for extended periods. The generator is designed to run on standard propane or natural gas, giving users flexibility in fuel choices.

The generator is also equipped with multiple outlets, including 120V and 240V options, enabling users to connect various devices simultaneously. The inclusion of a 12V DC outlet adds versatility, allowing it to charge batteries and small electronics. Furthermore, the CGN10RL features built-in circuit breakers that protect against overloads, enhancing safety for users.

Portability is another key characteristic of the Desa CGN10RL. It comes with heavy-duty wheels and a comfortable handle, making transportation to different locations effortless. Its compact design allows for easy storage when not in use.

In summary, the Desa CGN10RL generator stands out with its powerful engine, advanced noise reduction, impressive fuel efficiency, versatile output options, and portability. These features make it a reliable choice for users looking for a high-quality generator that can handle a variety of applications while maintaining ease of use and safety.