Desa CGN30D, CGN18RA Operating Heater Inspecting Burner, Pilot Flame Pattern, Shutting Off Heater

Models: CGN30D CGN18RA

1 32
Download 32 pages 61.11 Kb
Page 20
Image 20

20

OPERATING HEATER

Continued

INSPECTING BURNER

 

 

TO TURN OFF GAS TO APPLIANCE

 

 

 

 

 

 

 

Shutting Off Heater

1.

Turn control knob clockwise Clockwise to the OFF position.

2.

Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

1.

Turn control knob clockwise Clockwise to the PILOT position.

MANUAL LIGHTING PROCEDURE

1.Follow steps 1 through 6 under Lighting Instructions, pages 17 and 18.

2.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

3.Keep control knob pressed in for 10 seconds after lighting pilot. After 10 seconds, release control knob.

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

Pilot Burner

Thermocouple

GOOD PILOT

GRH/OV 009

Figure 18 - Correct Pilot Flame Pattern

Thermocouple

Pilot Burner

 

BAD PILOT

GRH/OV 010

Figure 19 - Incorrect Pilot Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 19

turn heater off (see To Turn Off Gas to Appliance, above)

see Troubleshooting, pages 22 through 25

101826

Page 20
Image 20
Desa CGN30D, CGN18RA installation manual Operating Heater Inspecting Burner, Pilot Flame Pattern, Shutting Off Heater