![](/images/new-backgrounds/1054638/5463849x1.webp)
TROUBLE- | WARNING | |
SHOOTING |
| |
If you smell gas | ||
Continued | • Shut off gas supply. | |
• Do not try to light any appliance. | ||
|
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
| IMPORTANT: Operating heater where impurities in air exist may create odors. | |||||||||
| Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new | |||||||||
| carpet or textiles, etc., create fumes. These fumes may mix with combustion air and | |||||||||
| create odors. |
|
|
|
|
|
|
| ||
|
| OBSERVED | POSSIBLE |
|
|
|
|
| ||
|
| PROBLEM | CAUSE | REMEDY | ||||||
|
|
|
|
|
|
|
| |||
|
| Heater produces | 1. | Heater burning vapors | 1. | Ventilate room. Stop | ||||
|
| unwanted odors |
| from paint, hair spray, |
| using odor causing | ||||
|
|
|
| glues, etc. See IMPOR- |
| products while heater is | ||||
|
|
|
| TANT statement above |
| running | ||||
|
|
| 2. | Low fuel supply | 2. | Refill supply tank | ||||
|
|
| 3. | Gas leak. See Warn- | 3. | Locate and correct all | ||||
|
|
|
| ing statement at |
| leaks (see Checking Gas | ||||
|
|
|
| top of page |
| Connections, page 15) | ||||
|
|
|
|
|
|
|
|
| ||
|
| Heater shuts off in | 1. | Not enough fresh air is | 1. | Open window and/or | ||||
|
| use (ODS operates) |
| available |
| door for ventilation | ||||
|
|
| 2. | Low line pressure | 2. | Contact local natural | ||||
|
|
|
|
|
| gas company | ||||
|
|
| 3. | ODS/pilot is partially | 3. | Clean ODS/pilot (see | ||||
|
|
|
| clogged |
| Cleaning and Mainte- | ||||
|
|
|
|
|
| nance, page 22) | ||||
|
|
|
|
|
|
|
|
| ||
|
| Gas odor even when | 1. | Gas leak. See Warn- | 1. | Locate and correct all | ||||
|
| control knob is in |
| ing statement at |
| leaks (see Checking Gas | ||||
|
| OFF position |
| top of page |
| Connections, page 15) | ||||
|
|
| 2. | Control valve defective | 2. | Replace control valve | ||||
|
|
|
|
|
|
|
|
| ||
|
| Gas odor during | 1. | Foreign matter be- | 1. | Take apart gas tubing | ||||
|
| combustion |
| tween control valve |
| and remove foreign | ||||
|
|
|
| and burner |
| matter | ||||
|
|
| 2. | Gas leak. See Warn- | 2. | Locate and correct all | ||||
|
|
|
| ing statement at |
| leaks (see Checking Gas | ||||
|
|
|
| top of page |
| Connections, page 15) | ||||
|
|
|
|
|
|
|
| |||
|
| Moisture/condensation | 1. | Not enough combus- | 1. | Refer to Air for Com- | ||||
|
| noticed on windows |
| tion/ventilation air. |
| bustion and Ventilation | ||||
|
|
|
|
|
| requirements (page 5) | ||||
TECHNICAL | You may have further questions about installation, operation, or troubleshooting. | |||||||||
If so, contact DESA International’s Technical Service Department at | ||||||||||
SERVICE | ||||||||||
5190. |
|
|
|
| 25 |
101826