OPERATING

OPERATING

4. Wait five (5) minutes to clear out any gas. Then smell for gas, including

near the floor. If you smell gas, STOP! Follow “B” in the safety information

HEATER

at the top of page 12. If you don’t smell gas, go to the next step.

Continued

5. Press in control knob and turn counterclockwise

C-clockwise to the PILOT

 

 

position. Keep control knob pressed in for five (5) seconds (see Figure 15,

 

page 16).

 

 

Note: You may be running this heater for the first time after hooking up

 

to gas supply. If so, the control knob may need to be pressed in for 30

 

seconds. This will allow air to bleed from the gas system.

 

• If control knob does not pop up when released, contact a qualified

 

service person or gas supplier for repairs.

 

 

6. With control knob pressed in, push down and release ignitor button. This

 

will light pilot. The pilot is attached to the front of burner. The pilot can be

 

seen through the glass panel. If needed, keep pressing ignitor button until

 

pilot lights.

 

 

Note: If pilot does not stay lit, refer to Troubleshooting, pages 20 through

 

23. Also contact a qualified service person or gas supplier for repairs.

 

Until repairs are made, light pilot with match. To light pilot with match,

 

see Manual Lighting Procedure, page 18.

 

 

Ignitor Electrode

 

Thermocouple

Pilot Burner

Figure 16 - Pilot

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

8.Turn control knob counterclockwise HEATERC-clockwiseto the HIGH position. The main burner should light. Set control knob to any heat level between HIGH and LOW. To turn control knob from HIGH to a lower setting, press in the

control knob and turn counterclockwise see Manual Lighting Procedure, page 18.C-clockwise .

Note: Both HIGH and LOW are locked positions. You must press in control knob before turning it from these positions.

Manual background CAUTION

Do not try to adjust heating levels by using the manual shutoff valve.

Continued

17

 

103546

Page 17
Image 17
Desa CGN10L, CGN6L installation manual Heater, Operating, Continued, see Manual Lighting Procedure, page