Image 14
Checking Gas Connections, page 9)

GAS RESIDENTIAL HEATERS

TROUBLESHOOTING

Continued

Refer to Air for Combustion and WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where im- purities in air exist may create odors. Clean- ing supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVEDPROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces unwanted odors

1.

Heater burning vapors from paint, hair

1.

Ventilate room. Stop using odor-causing

 

 

spray, glues, etc. (See IMPORTANT

 

products while heater is running

 

 

statement above

 

 

 

2.

Low fuel supply

2.

Refill supply tank

 

3.

Gas leak. See Warning statement at top

3.

Locate and correct all leaks (see

 

 

of page

 

Checking Gas Connections, page 9)

 

 

 

 

 

Heater shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Refer to Air for Combustion and

 

 

 

 

Ventilation requirements (page 3)

 

2.

Low line pressure

2.

Contact local propane/LP gas company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 15)

Gas odor even when control knob is in OFF 1.

Gas leak. See Warning statement at top

position

of page

2.

Control valve defective

1.Locate and correct all leaks (see Checking Gas Connections, page 9)

2.Replace control valve

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement at top

 

 

of page

1.Take apart gas tubing and remove foreign matter

2.Locate and correct all leaks (see Checking Gas Connections, page 9)

Moisture/condensation noticed on windows 1. Not enough combustion/ventilation air

1. Refer to Air for Combustion and

 

Ventilation requirements (page 3)

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or Trouble Shooting. If so, contact DESA International’s Techni- cal Service Department at 1-800-323-5190.

SERVICE HINTS

When gas pressure is too low

pilot will not stay lit

burner(s) will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low

When gas quality is bad

pilot will not stay lit

burner(s) will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP gas supplier.

14