CONNECTING | IMPORTANT: Hold pressure regulator with wrench when connecting it to gas | ||
| |||
TO GAS | piping and/or fittings. |
|
|
|
|
| |
SUPPLY |
|
|
|
Continued |
|
|
|
|
| Pressure | |
|
| Regulator | |
| 3/8" NPT | Heater | |
| Pipe Nipple | ||
| Cabinet | ||
|
| ||
| Ground Joint |
|
|
| Union | Tee Joint |
|
|
|
| |
| Manual Shutoff | Reducer | Test |
| Valve * | Bushing to | Gauge |
| From | 1/8" NPT | Connection * |
|
| ||
| External | 1/8" NPT |
|
| Regulator |
| |
| Plug Tap |
| |
| (11" W.C. to |
| |
| Tee |
| |
| 14" W.C. Pressure) |
| |
| Joint |
| |
|
|
| |
| 3" Minimum | Pipe | Sediment Trap |
|
| ||
|
| Nipple |
|
|
| Cap |
|
| Figure 13 - Gas Connection |
|
*An A.G.A. design certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design certified manual shutoff valve from your dealer. See Accessory, page 26.
CHECKING | WARNING |
GAS |
|
Test all gas piping and connections for leaks after installation or | |
CONNECTIONS | servicing. Correct all leaks at once |
| |
|
|
| WARNING |
| Never use an open flame to check for a leak. Apply a mixture of |
| liquid soap and water to all joints. Bubbles forming show a leak. |
| Correct all leaks at once. |
|
|
|
|
| CAUTION |
| Make sure external regulator has been installed between propane |
| supply and heater. See guidelines under Connecting to Gas Supply, |
| page 13. |
|
|
PRESSURE TESTING GAS SUPPLY PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG
1.Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.
2.Cap off open end of gas pipe where manual shutoff valve was connected.
14
100846