Desa CGP11A installation manual Trouble, Shooting, Cleaning, Maintenance, Continued

Models: CGP11A

1 28
Download 28 pages 9.5 Kb
Page 21
Image 21
CLEANING

CLEANING

 

WARNING

AND

WARNING ICONG 001

Turn off heater and let cool before cleaning.

MAINTENANCE

 

 

 

 

 

 

WARNING ICONG 001

CAUTION

 

 

You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.

ODS/PILOT AND BURNER ORIFICE

• Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

TROUBLE-

 

 

WARNING ICONG 001WARNING

 

 

 

 

 

SHOOTING

 

 

 

 

 

 

 

Turn off heater and let cool before servicing. Only a qualified

 

 

Note: All troubleshooting

service person should service and repair heater.

 

 

 

 

 

 

 

 

 

 

items are listed in order of

 

 

 

 

 

 

 

 

 

 

WARNING ICONG 001CAUTION

 

 

 

 

 

operation.

 

 

 

 

 

 

 

 

Never use a wire, needle, or similar object to clean ODS/pilot. This

 

 

 

can damage ODS/pilot unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OBSERVED

POSSIBLE

 

 

 

 

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

 

 

 

 

 

 

When ignitor button

1.

Ignitor electrode posi-

1.

Replace ignitor

 

 

 

is pressed and control

 

tioned wrong

 

 

 

 

 

 

knob is pressed in

2.

Ignitor electrode broken

2.

Replace ignitor

 

 

 

and turned to the

3.

Ignitor electrode not

3.

Reconnect ignitor cable

 

PILOT position,

 

connected to ignitor

 

 

 

 

 

 

there is no spark at

 

cable

 

 

 

 

 

 

ODS/pilot

4.

Ignitor cable pinched or

4.

Free ignitor cable if

 

 

 

 

 

wet

 

pinched by any metal or

 

 

 

 

 

tubing. Keep ignitor

 

 

 

 

5. Piezo ignitor nut is loose

 

cable dry

 

 

 

 

 

 

5.

Tighten nut holding

 

 

 

 

 

 

 

piezo ignitor to heater

 

 

 

 

 

 

 

cabinet. Nut is located

 

 

 

 

 

 

 

inside heater cabinet at

 

 

6.

Broken ignitor cable

 

top

 

 

 

 

7.

Bad piezo ignitor

6.

Replace ignitor cable

 

 

 

 

 

 

7.

Replace control valve

 

 

 

 

 

 

 

(piezo is part of control

 

 

 

 

 

valve)

 

 

 

 

 

 

 

Continued

 