CHECKING

CHECKING

3.

Pressurize supply piping system by either using compressed air or

 

opening propane/LP supply tank valve.

GAS

 

4.

Check all joints of gas supply piping system. Apply mixture of liquid soap and

CONNECTIONS

 

water to gas joints. Bubbles forming show a leak.

5.

Correct all leaks at once.

Continued

Test Pressures Equal To or Less Than 1/2 PSIG

 

 

1.

Close manual shutoff valve (see Figure 14).

 

2.

Pressurize supply piping system by either using compressed air or opening

 

 

propane/LP supply tank valve.

 

3.

Check all joints from propane/LP supply tank to manual shutoff valve (see

 

 

Figure 15). Apply mixture of liquid soap and water to gas joints. Bubbles

 

 

forming show a leak.

 

4.

Correct all leaks at once.

PRESSURE TESTING HEATER GAS CONNECTIONS

1.Open manual shutoff valve (see Figure 14).

2.Open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from manual shutoff valve to control valve (see Figure 15). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 17 through 20). Check the rest of the internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 20).

8.Replace front panel.

OpenN

POSITION

Manual

Shutoff

Valve

OFF

ClosedPOSITION

Figure 14 - Manual Shutoff Valve

Control Valve Location

Propane/LP

Supply Tank

16

Manual

Shutoff

Valve

Figure 15 - Checking Gas Joints

101827

Page 16
Image 16
Desa CGP16RA, CGP26D installation manual Checking, Continued, Pressure Testing Heater Gas Connections