Desa CGP26D, CGP16RA installation manual Trouble, Shooting, Continued, When control knob is

Models: CGP26D CGP16RA

1 32
Download 32 pages 55.88 Kb
Page 23
Image 23
Manual background

TROUBLE-

OBSERVED

POSSIBLE

 

 

 

PROBLEM

CAUSE

REMEDY

SHOOTING

 

 

 

 

 

 

When control knob is

1. Gas supply turned off

1.

Turn on gas supply or

Continued

 

pressed in and turned

 

or manual shutoff

 

open manual shutoff

 

to the PILOT/IGN

 

valve closed

 

valve

 

position, there is

2.

Control knob not

2.

Press in control knob

 

spark at ODS/pilot

 

pressed in while being

 

while turning to

 

but no ignition

 

turned to PILOT/IGN

 

PILOT/IGN position

 

 

 

position

 

 

 

 

 

3.

Air in gas lines when

3.

Continue holding down

 

 

 

installed

 

control knob. Repeat

 

 

 

 

 

igniting operation until

 

 

 

 

 

air is removed

 

 

4.

Depleted gas supply

4.

Contact local propane/

 

 

 

 

 

LP gas company.

 

 

5.

ODS/pilot is clogged

5.

Clean ODS/pilot (see

 

 

 

 

 

Cleaning and Mainte-

 

 

 

 

 

nance, page 22) or

 

 

 

 

 

replace ODS/pilot

 

 

 

 

 

assembly

 

 

6.

Gas regulator setting is

6.

Replace gas regulator

 

 

 

not correct

 

 

 

 

 

 

 

 

 

 

 

ODS/pilot lights but

1.

Control knob not fully

1.

Press in control knob

 

flame goes out when

 

pressed in

 

fully

 

control knob is

2.

Control knob not

2.

After ODS/pilot lights,

 

released

 

pressed in long enough

 

keep control knob

 

 

 

 

 

pressed in 10 seconds

 

 

3.

Manual shutoff valve

3.

Fully open manual

 

 

 

not fully open

 

shut-off valve

 

 

4.

Thermocouple connec-

4.

Hand tighten until

 

 

 

tion loose at control

 

snug, then tighten 1/4

 

 

 

valve

 

turn more

 

 

5.

Pilot flame not touch-

5.

A) Contact local

 

 

 

ing thermocouple,

 

propane/LP gas

 

 

 

which allows thermo-

 

company

 

 

 

couple to cool, causing

 

 

 

 

 

 

pilot flame to go out.

 

B) Clean ODS/pilot

 

 

 

This problem could be

 

(see Cleaning and

 

 

 

caused by one or both

 

Maintenance, page 22)

 

 

 

of the following:

 

or replace ODS/pilot

 

 

 

A) Low gas pressure

 

assembly

 

 

 

B) Dirty or partially

 

 

 

 

 

 

clogged ODS/pilot

 

 

 

 

 

6.

Thermocouple dam-

6.

Replace thermocouple

 

 

 

aged

 

 

 

 

 

7.

Control valve damaged

7.

Replace control valve

Continued

101827

23

Page 23
Image 23
Desa CGP26D, CGP16RA installation manual Trouble, Shooting, Continued, When control knob is