TROUBLE- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| WARNING |
|
|
|
|
|
|
|
| |
SHOOTING |
|
|
| If you smell gas |
|
|
|
|
|
|
|
| ||
Continued |
|
|
| • Shut off gas supply. |
|
|
|
|
|
|
|
| ||
|
|
| • Do not try to light any appliance. |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
| • Do not touch any electrical switch; do not use |
|
|
|
|
| |||||
|
|
|
| any phone in your building. |
|
|
|
|
|
|
|
| ||
|
|
|
| • Immediately call your gas supplier from a |
|
|
|
|
| |||||
|
|
|
| neighbor’s phone. Follow the gas supplier’s |
|
|
|
|
| |||||
|
|
|
| instructions. |
|
|
|
|
|
|
|
| ||
|
|
|
| • If you cannot reach your gas supplier, call the |
|
|
|
|
| |||||
|
|
|
| fire department. |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |||||
|
| IMPORTANT: Operating heater where impurities in air exist may create odors. |
| |||||||||||
|
| Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new |
| |||||||||||
|
| carpet or textiles, etc., create fumes. These fumes may mix with combustion air and |
| |||||||||||
|
| create odors. |
|
|
|
|
|
|
|
|
|
| ||
|
|
| OBSERVED | POSSIBLE |
|
|
|
|
|
|
|
| ||
|
|
| PROBLEM | CAUSE | REMEDY |
| ||||||||
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
| Heater produces | 1. | Heater burning vapors | 1. | Ventilate room. Stop |
| ||||||
|
|
| unwanted odors |
| from paint, hair spray, |
| using odor causing |
| ||||||
|
|
|
|
|
| glues, etc. See IMPOR- |
| products while heater is |
| |||||
|
|
|
|
|
| TANT statement above |
| running |
| |||||
|
|
|
|
| 2. | Low fuel supply | 2. | Refill supply tank |
| |||||
|
|
|
|
| 3. | Gas leak. See Warn- | 3. | Locate and correct all |
| |||||
|
|
|
|
|
| ing statement at |
| leaks (see Checking Gas |
| |||||
|
|
|
|
|
| top of page |
| Connections, page 15) |
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| Heater shuts off in | 1. | Not enough fresh air is | 1. | Open window and/or |
| ||||||
|
|
| use (ODS operates) |
| available |
| door for ventilation |
| ||||||
|
|
|
|
| 2. | Low line pressure | 2. | Contact local propane/ |
| |||||
|
|
|
|
|
|
|
| LP gas company |
| |||||
|
|
|
|
| 3. | ODS/pilot is partially | 3. | Clean ODS/pilot (see |
| |||||
|
|
|
|
|
| clogged |
| Cleaning and Mainte- |
| |||||
|
|
|
|
|
|
|
| nance, page 22) |
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| Gas odor even when | 1. | Gas leak. See Warn- | 1. | Locate and correct all |
| ||||||
|
|
| control knob is in |
| ing statement at |
| leaks (see Checking Gas |
| ||||||
|
|
| OFF position |
| top of page |
| Connections, page 15) |
| ||||||
|
|
|
|
| 2. | Control valve defective | 2. | Replace control valve |
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| Gas odor during | 1. | Foreign matter be- | 1. | Take apart gas tubing |
| ||||||
|
|
| combustion |
| tween control valve |
| and remove foreign |
| ||||||
|
|
|
|
|
| and burner |
| matter |
| |||||
|
|
|
|
| 2. | Gas leak. See Warn- | 2. | Locate and correct all |
| |||||
|
|
|
|
|
| ing statement at |
| leaks (see Checking Gas |
| |||||
|
|
|
|
|
| top of page |
| Connections, page 15) |
| |||||
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
| Moisture/condensation | 1. | Not enough combus- | 1. | Refer to Air for Com- |
| ||||||
|
|
| noticed on windows |
| tion/ventilation air. |
| bustion and Ventilation |
| ||||||
|
|
|
|
|
|
|
| requirements (page 5) |
| |||||
TECHNICAL |
| You may have further questions about installation, operation, or troubleshooting. |
| |||||||||||
| If so, contact DESA International’s Technical Service Department at |
| ||||||||||||
SERVICE |
|
| ||||||||||||
5190. |
|
|
|
|