Desa CGP20B, CGP20LB, RP30E Check Gas Type, Installation Items, Locating Heater

Models: RP30E CGP20B CGP20LB

1 24
Download 24 pages 20.92 Kb
Page 7
Image 7
INSTALLATION

OWNER’S MANUAL

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

CHECK GAS TYPE WARNING: A qualified ser- vice person must install heater. Follow all local codes.

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply is not propane/LP, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION ITEMS

Before installing heater, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

ground joint union

test gauge connection *

sediment trap

tee joint

pipe wrench

*A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an ac- ceptable alternative to test gauge connec- tion. Purchase the optional CSA/AGA de- sign-certified equipment shutoff valve from your dealer. See Accessories, page 22.

LOCATING HEATER

This heater is designed to be mounted on a wall.

INSTALLATION ITEMS WARNING: Maintain the mini- mum clearances shown in Figure

4.If you can, provide greater clear- ances from floor, ceiling, and join- ing wall.

You can locate model CGP20B and CGP20LB on floor, away from a wall. An optional floor mounting stand is needed. Purchase the floor mounting stand from your dealer. See Accessories, page 22.

LOCATING HEATER WARNING: Never install the heater

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

Manual background CAUTION: This heater cre- ates warm air currents. These cur- rents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall cover- ings or operating heater where impurities (such as tobacco smoke, aromatic candles, oil or kerosene lamps, etc.) in the air exist, may discolor walls.

IMPORTANT: Vent-free heaters add mois- ture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Com- bustion and Ventilation, pages 4 through 6.

Manual background CAUTION: If you install the heater in a home garage

heater pilot and burner must be at least 18 inches above floor

locate heater where moving vehicle will not hit it

For convenience and efficiency, install heater

where there is easy access for operation, inspection, and service

where strong wind gusts from an open door or garage door can not blow directly into heater.

An optional fan kit is available from your dealer. See Accessories, page 22. If plan- ning to use fan, locate heater near an electri- cal outlet.

CEILING

6" Minimum

from Sides of36"

HeaterMinimum

Left

SideRight

Side

*Minimum To

FLOORTop Surface

of Carpeting, Tile or

Other Combustible

Material RP30E-16 3/4"

CGP20(L)B - 3"

Figure 4 - Mounting Clearances As Viewed From Front of Heater

Continued

104412

7

Page 7
Image 7
Desa CGP20B, CGP20LB, RP30E installation manual Check Gas Type, Installation Items, Locating Heater