Desa CG6P, CGS10P, CG10P Checking Gas Connections, Propane/Lp Gas Heater, Installation, Continued

Models: CG10P CG6P CGS10P

1 26
Download 26 pages 22.09 Kb
Page 10
Image 10
CHECKING GAS

PROPANE/LP GAS HEATER

INSTALLATION

Continued

CHECKING GAS

CONNECTIONS

Pressure Testing Heater Gas Connections WARNING: Test all gas pip- ing and connections for leaks after installation or servicing. Correct all leaks at once.

Pressure Testing Gas Supply Piping SystemWARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

Manual background CAUTION: Make sure exter- nal regulator has been installed between propane/LP supply and heater. See guidelines under Con- necting to Gas Supply, page 9.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Fig- ure 15).

2.Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve.

3.Check all joints from propane/LP sup- ply tank to equipment shutoff valve (see Figure 16). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Equipment

Open

Shutoff Valve

Closed

Figure 15 - Equipment Shutoff Valve

Pressure Testing Heater Gas Connections

1.Open equipment shutoff valve (see Fig- ure 15).

2.Open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to control valve (see Figure 16). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, page 11 for non-thermostat models or pages 12 and 13 for thermostat model). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas To Appliance, page 11 for non-thermo- stat models or page 12 for thermostat model).

8.Replace front panel.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve.

4.Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

5.Correct all leaks at once.

6.Reconnect heater and equipment shutoff valve to gas supply. Check re- connected fittings for leaks.

Propane/LP

Supply Tank

Figure 16 - Checking Gas Joints

Manual background Control

Valve

Location

Equipment

Shutoff Valve

10

107295

Page 10
Image 10
Desa CG6P, CGS10P, CG10P installation manual Checking Gas Connections, Propane/Lp Gas Heater, Installation, Continued