Desa CGS3124N, CLD3018NA Installation, Continued, Minimum Noncombustible Material Clearances

Models: CLD3018PA CLD3018NA CGS3124N CGS2718P, CGS2718N, CGS3124P, CGS3124P, CGS3124N, CLD3018PA, CLD3018NA, CLD3924PTA, CLD3924NTA

1 36
Download 36 pages 23.79 Kb
Page 8
Image 8
Minimum Noncombustible Material Clearances

8

INSTALLATION

Installation and Clearances (Cont.)

INSTALLATION

Continued

NOTICE: Manual control heaters may be used as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fire- place opening is not needed. Go to Installing Damper Clamp Accessory for Vented Operation, page 10.

Minimum Noncombustible Material Clearances

If Not Using Mantel

Note: If using a mantel, proceed to If Using Mantel. If not using a mantel, follow the information below.

You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible material must extend at least 8" up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" model only). See Figure 5 at right for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Install- ing Damper Clamp Accessory for Vented Operation, page 10.

If Using Mantel

You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible material must extend at least 8 inches up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" model only). Even if noncombustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and Figures 6 and 7 on page 9 for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Install- ing Damper Clamp Accessory for Vented Operation, page 10.

Noncombustible

Requirements for
Material Distance (A)
Safe Installation

 

 

12" or more

Noncombustible material okay.

Between 8" and 12"

24" Model: Install fireplace hood

 

accessory (GA6050, GA6052,

 

or GA6053, see Accessories,

 

page 32).

 

18" Model: Noncombustible

 

material okay.

Less than 8"

Noncombustible material must

 

be extended to at least 8". See

 

Between 8" and 12", above. If

 

you cannot extend material, you

 

must operate heater with flue

 

damper open.

 

 

Heat Resistant Noncombustible

Material

(A)

Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

Requirements forMaterial Distance (A)Safe InstallationBetween 8" and 12", above. IfManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

107068

Page 8
Image 8
Desa CGS3124N Installation, Continued, Minimum Noncombustible Material Clearances, Requirements for, Material Distance A

FAQ

What are the minimum noncombustible material clearances for Desa electric heaters?

The minimum noncombustible material clearances for Desa electric heaters depend on the distance of the material from the fireplace. It is important to follow the specific guidelines for safe installation.

Do I need a fireplace hood accessory for my Desa electric heater?

If the noncombustible material is less than 12 inches from the fireplace opening, you may need to install the fireplace hood accessory to meet the minimum clearances. Consult the installation manual for details.

What should I do if I cannot meet the minimum clearances for my Desa electric heater?

If you cannot meet the minimum clearances for your Desa electric heater, you must operate the heater with the chimney flue damper open. Refer to the manual for instructions on installing the damper clamp accessory for vented operation.