Desa CLD3018NA, CGS3124N, CLD3018PA Mantel Clearances, Floor Clearances, Installation, Continued

Models: CLD3018PA CLD3018NA CGS3124N CGS2718P, CGS2718N, CGS3124P, CGS3124P, CGS3124N, CLD3018PA, CLD3018NA, CLD3924PTA, CLD3924NTA

1 36
Download 36 pages 23.79 Kb
Page 9
Image 9
MANTEL CLEARANCES

INSTALLATION

9

Mantel Clearances

Floor Clearances

 

 

 

INSTALLATION

Continued

MANTEL CLEARANCES

In addition to meeting noncombustible material clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet the clearances listed below, you will need a hood.

Determining Minimum Mantel Clearance

If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6).

10"

8"

6"

2 1/2"

Minimum Non-

 

 

(A)

 

Combustible

 

Material

12"

 

 

 

 

 

 

8"

 

 

 

 

Mantel Shelf

18"

 

20"

22"

 

8"

 

14"

17"

 

 

 

 

Underside of

Mantel Shelf

All minimum distances are in inches

Log Set

24" FLOOR CLEARANCES 24" Model

20" Manual background 18" Model

Top of Fireplace

Opening

Determining Minimum Mantel Clearance when Using a Hood

If minimum clearances in Figure 6 are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clearances shown in Figure 7 when using a hood.

NOTICE: Surface temperatures of adjacent walls and

Minimum Non-

Distances to

Combustible

Underside of

Material Height

Mantel

Figure 6 - Minimum Mantel Clearances Without Using Hood

Mantel Shelf

mantels become hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual.

NOTICE: If your installation does not meet the mini- mum clearances shown, you must do one of the following:

operate the logs only with the flue damper open

raise the mantel to an acceptable height

remove the mantel

FLOOR CLEARANCES

 

12"

 

 

 

10"

 

 

 

8"

 

 

 

6"

 

 

 

2 1/2"

 

 

Minimum Non-

 

 

 

Combustible

 

 

 

Material

8"

12"

15"

 

 

Min.

 

 

 

Hood

Distances to

 

(GA6050, GA6052,

 

Underside of

 

or GA6053)

 

Mantel

 

 

18"

Underside of

Mantel Shelf

All minimum distances are in inches

Log Set

20"Manual background 18" and 24" Models

Top of Fireplace Opening

A.If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8).

B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combustible floor- ing (see Figure 9).

Figure 7 - Minimum Mantel Clearances When Using Hood

 

Combustible

Hearth

14"

Material

 

Combustible

Min.

 

Material

 

 

5"

 

 

Min.

Noncombustible Material

 

Figure 8 - Minimum Fireplace

Figure 9 - Minimum Fireplace

Clearances If Installed at Floor

Clearances Above

Level

 

Combustible Flooring

For moreManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

107068

Page 9
Image 9
Desa CLD3018NA, CGS3124N, CLD3018PA installation manual Mantel Clearances, Floor Clearances, Installation, Continued

FAQ

What are the mantel clearances for Desa Electric Heaters?

Mantel clearances are detailed in the official manual for Desa Electric Heaters, including noncombustible material clearances and required clearances between the fireplace opening and mantel shelf.

When is a hood required for Desa Electric Heaters?

A hood is required if the minimum clearances between the mantel shelf and top of the fireplace opening are not met. Detailed instructions can be found in the manual.

How can I ensure proper floor clearances for Desa Electric Heaters?

Proper floor clearances for Desa Electric Heaters are outlined in the official manual, including minimum distances to combustible materials and the minimum distance required if installing the appliance on the floor level.