Desa installation manual Floor Clearances, Log Set

Models: CGS2718PA, CGS2718NA, CGS3124PA, CGS3124NA, SGS3124PA, SGS3124NA,CLD3018PTA, CLD3018NTA, CLD3924NTB, CLD3924PTB

1 36
Download 36 pages 51.65 Kb
Page 11
Image 11

INSTALLATION

Continued

NOTICE: If your installation does not meet the minimum clear- ances shown, you must do one of the following:

operate the logs only with the flue damper open

raise the mantel to an accept- able height

remove the mantel

FLOOR CLEARANCES

A.If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8).

B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combustible flooring (see Figure 9).

Mantel Shelf

12"

10"

8"

6"

2 1/2"

Underside of Mantel Shelf

All minimum distances are

Minimum Non-

Combustible

Material

8"

Min.

12"

15"

18"

in inches

Log Set

20"18" and 24" Models

Top of Fireplace Opening

Hood

(GA6050, GA6052 or GA6053)

Distances to Underside of Mantel

Figure 7 - Minimum Mantel Clearances When Using Hood

 

Combustible

Hearth

 

14"

Material

Combustible

 

 

Min.

 

 

Material

 

 

5"

 

 

 

Min.

 

Noncombustible Material

 

 

Figure 8 - Minimum Fireplace Clearances

Figure 9 - Minimum Fireplace Clearances

If Installed at Floor Level

Above Combustible Flooring

113101-01C