Desa CRL3124N Specifications, Logs, Dual Burner Biltmore Split Oak Models, Continued, Main Burner

Models: CGD3018NT CCL3924N CGD3924NT CCL3018N CCL3018NT CRL2718N CRL3124N

1 40
Download 40 pages 2.22 Kb
Page 21
Image 21
SPECIFICATIONS

CLEANING AND MAINTENANCE

Cleaning Burner Injector Holder and Pilot Air Inlet Hole (Cont.)

Logs

Main Burner

SPECIFICATIONS

21

CLEANING AND MAINTENANCE

Continued

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.

SPECIFICATIONS

Dual Burner Smoky Mountain Oak and Premium Aged Split Oak Models

 

18" Model

24" Models

30" Models

Btu (Variable)

16,000/30,000

20,000/39,000

20,000/39,000

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 45). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Burner

 

Tube

Injector Holder

Primary Air

Inlet Holes

Figure 44 - Injector Holder On Outlet Burner Tube

Ports/Slots

Burner

Tube

Pilot Assembly

Pilot Air

Inlet Hole

Figure 45 - Pilot Inlet Air Hole

LOGS

If you remove logs for cleaning, refer to Installing Logs, pages 13 through 16, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

Type Gas

 

Natural Gas Only

 

Ignition Piezo

Piezo

Piezo

 

Manifold Pressure

3.5" W.C.

3.5" W.C.

3.5" W.C.

Inlet Gas

 

 

 

Pressure (in. of water)

 

 

 

Maximum

10.5"

10.5"

10.5"

Minimum*

5"

5"

5"

Shipping Weight

36 lbs.

38 lbs.

40 lbs.

* For the purpose of input adjustment

Dual Burner Biltmore Split Oak Models

 

18" Model

24" Models

30" Models

Btu (Variable)

16,000/30,000

20,000/39,000

20,000/39,000

Type Gas

 

Natural Gas Only

 

Ignition Piezo

Piezo

Piezo

 

Manifold Pressure

3.5" W.C.

3.5" W.C.

3.5" W.C.

Inlet Gas

 

 

 

Pressure (in. of water)

 

 

 

Maximum

10.5"

10.5"

10.5"

Minimum*

5"

5"

5"

Shipping Weight

61 lbs.

66 lbs.

70 lbs.

* For the purpose of input adjustment

Single Burner Seasonal Oak Models

 

18" Model

24" Model

Btu (Variable)

16,000/27,000

16,000/31,500

Type Gas

Natural Gas Only

Ignition Piezo

Piezo

 

Manifold Pressure

3.5" W.C.

3.5" W.C.

Inlet Gas

 

 

Pressure (in. of water)

 

 

Maximum

10.5"

10.5"

Minimum*

5"

5"

Shipping Weight

TBA lbs.

TBA lbs.

* For the purpose of input adjustment

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool, Remove blockage, blocked burner flame holes will create soot.

LOGSFor moreDual Burner Biltmore Split Oak ModelsSingle Burner Seasonal Oak ModelsTBA lbs.Manual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

107123-01E

Page 21
Image 21
Desa CRL3124N Specifications, Logs, Dual Burner Biltmore Split Oak Models, Single Burner Seasonal Oak Models, Continued