Desa D30H Air Output, Air Intake, And Lint Filters, Pump Pressure Adjustment, Service Procedures

Models: D20H D30H D44H

1 22
Download 22 pages 32.71 Kb
Page 10
Image 10
AIR OUTPUT, AIR INTAKE, AND LINT FILTERS

D20H, D30H AND D44H MODELS PORTABLE FORCED AIR HEATERS

SERVICE

PROCEDURES

Continued

AIR OUTPUT, AIR INTAKE, AND LINT FILTERS

1.Remove upper shell (see page 8).

2.Remove filter end cover screws using 5/16" nut-driver.

3.Remove filter end cover.

4.Replace air output and lint filters.

5.Wash or replace air intake filter (see Preventative Maintenance Schedule, page 6).

6.Replace filter end cover.

7.Replace fan guard and upper shell.

IMPORTANT: Do not oil filters

PUMP PRESSURE

ADJUSTMENT

1.Remove pressure gauge plug from filter end cover.

2.Install accessory pressure gauge (part number HA1180).

3.Start heater (see Operation, page 5). Allow motor to reach full speed.

4.Adjust pressure. Turn relief valve to right to increase pressure. Turn relief valve to left to decrease pressure. See specifications below for correct pres- sure for each model.

5.Remove pressure gauge. Replace pres- sure gauge plug in filter end cover.

Air Intake Filter

Filter End

Fan Guard

Cover

Lint Filter

Air Output

Filter

Figure 13 - Air Output, Air Intake, and Lint Filters, D20H Model

Air Intake Filter

Filter End

Fan Guard

Cover

 

Lint Filter

Air Output

Filter

Figure 14 - Air Output, Air Intake, and Lint Filters, D30H and D44H Models

Pressure

 

 

Gauge

 

Pump

Plug

 

Relief

 

Pressure

Model

(PSI/Bar)

Valve

D20H

4.7/0.324

 

 

D30H

4.9/0.338

 

D44H

5.5/0.380

Figure 15 - Pressure Gauge Plug Removal

(D20H Model Shown)

Pressure

Gauge

Figure 16 - Adjusting Pump Pressure

10

105843

Page 10
Image 10
Desa D30H, D44H, D20H Air Output, Air Intake, And Lint Filters, Pump Pressure Adjustment, Service Procedures, Continued