11
107205
OWNER’S MANUAL
For more information, visit www.desatech.com
VENTING
INSTALLATION
Continued
UP
Venting with Two 90° Elbows
Vertical (V) Horizontal (H1) Horizontal (H1) +
Horizontal (H2)
5' min. 2' max. 6' max.
6' min. 4' max. 12' max.
7' min. 6' max. 18' max.
8' min. 8' min. 20' max.
20' max. 8' max. 20' max.
Venting with Two 90° Elbows
Vertical (V) Horizontal (H1) +
Horizontal (H2)
5' min. 6' max.
6' min. 12' max.
7' min. 18' max.
8' min. 20' max.
20' max. 20' max.
Figure 18 - Horizontal Termination Configuration for Rigid Venting Using Two 90
°
Elbows
Figure 19 - Horizontal Termination Configuration for Rigid Venting Using Two 90
°
Elbows with Termination at 90
°
with Fireplace
Continued
FD60
60˚ Starter/
Adapter Required
FD30
30˚ Starter/
Adapter Required
*
*
* Note: Remember to add 1/
4” rise per 12” horizontal
length of pipe.