DIRECT-VENT FIREPLACE

PRE-INSTALLATION PREPARATION

LOCATION AND SPACE REQUIREMENTS

Determine the safest and most efficient loca- tion for your FMI direct-vent fireplace. Make sure that rafters and wall studs are not in the way of the venting system. Choose a loca- tion where the heat output is not affected by drafts, air conditioning ducts, windows or doors. Figure 2 shows some common loca- tions. Read all venting information in this manual. Be aware of all restrictions and precautions before deciding the exact loca- tion for your fireplace.

When deciding the location of your fire- place, follow these rules:

1.Do not connect this fireplace to a chim- ney flue serving a separate solid-fuel burning fireplace or appliance.

2.Due to high temperatures, do not lo- cate this fireplace in high traffic areas or near furniture or draperies.

3.Proper clearances must be maintained.

4.If your fireplace is to be installed di- rectly on carpeting, vinyl tile, or any combustible material other than wood, it must be installed on a metal or wood panel extending the full width and depth of the fireplace. See Figure 3.

Flush with a wall

Through exterior wall enclosed in a chase

Corner installation

Figure 2 - Common Fireplace Locations

 

 

 

RW

 

 

 

D

 

 

 

 

 

 

FW

 

 

 

 

 

 

 

 

 

Fireplace size

D x FW x RW

34"

 

18 1/2" 34 3/8" 14"

CLEARANCES

Minimum clearances to combustibles for the fireplace are as follows:

Back, and sides

0"/mm

Perpendicular walls

6" (152mm)

Floor

0"/mm

Ceiling to louver opening

42" (1067mm)

Front

36" (914mm)

Top of Standoffs

0"/mm

See General Venting on pages 5 and 6 for specific venting clearances.

FRAMING AND FINISHING

Figures 4 and 5 show typical framing of this fireplace. Figure 6 on page 5 shows framing for corner installation. All minimum clear- ances must be met. Do not install fireplace directly on carpeting, vinyl tile, or any com- bustible material other than wood. The fire- place must set on a metal or wood panel extending the full width and depth of the fireplace.

See Accessories on page 34 for mantel kits available for this fireplace. If you are using a separate combustible mantel piece, refer to Figure 7 on page 5 for proper installation height. You can install noncombustible man- tels at any height above the fireplace. Note: Noncombustible mantels may discolor!

341/4"

343/4"

Must maintain a minimum 1" clearance to combustibles

34"

20"

5/8" for drywall facing

Figure 5 - Framing Clearances for Typical Fireplace Installation

20" Vertical Termination

19" Horizontal Termination

Figure 3 - Fireplace Bottom Dimensions

Figure 4 - Framing Clearances for Installation Against an Exterior Wall

For more information, visit www.desatech.com

4

107205

Page 4
Image 4
Desa DVFE34 PRE-INSTALLATION Preparation, Location and Space Requirements, Clearances, Framing and Finishing

DVFE34 specifications

Desa DVFE34 is a cutting-edge development designed to meet the demanding needs of modern urban living. This residential complex stands out due to its innovative architecture, sustainable technologies, and its commitment to enhancing the quality of life for its residents.

One of the main features of Desa DVFE34 is its environmentally friendly design. The complex has been constructed with sustainable materials that minimize its carbon footprint. Solar panels are integrated into the building's structure, providing renewable energy for common areas and reducing reliance on non-renewable power sources. The implementation of rainwater harvesting systems ensures efficient use of water resources, promoting sustainability within the community.

In terms of technology, Desa DVFE34 is equipped with smart home capabilities. Residents can control various aspects of their homes—from lighting to heating—through a centralized app on their smartphones. This not only adds convenience but also allows for energy savings and enhances security. The incorporation of security systems with smart alarms and surveillance cameras ensures a safe living environment.

The layout of the building is thoughtfully designed to maximize space and comfort. Spacious apartments come with modern finishes, high ceilings, and large windows that allow plenty of natural light to flow in. Common areas include beautifully landscaped gardens, recreational spaces, and fitness facilities that encourage a healthy lifestyle. Additionally, designated areas for social gatherings foster a sense of community among residents.

Accessibility is a key characteristic of Desa DVFE34. Located in a prime urban area, residents have easy access to public transport, shopping centers, and essential services. This not only facilitates daily commutes but also enhances the overall living experience by placing residents in the heart of the city’s amenities.

In summary, Desa DVFE34 represents a harmonious blend of modern living and sustainable practices. Its innovative features, from smart technologies to eco-friendly designs, set a new standard for urban residential developments. By prioritizing both comfort and sustainability, Desa DVFE34 is an exemplary model of what future living spaces can and should be.