Desa EFP33PR Specifications, Service Hints, Technical Service, Cleaning Pilot Air Inlet Hole

Models: EFP33NR EFP33PR

1 44
Download 44 pages 38.32 Kb
Page 27
Image 27
CLEANING PILOT AIR INLET HOLE

CLEANING AND

MAINTENANCE

Continued

CLEANING PILOT AIR INLET HOLE

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 58). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available. You may also clean the pilot air inlet hole by pushing a common pipe cleaner completely through the air inlet hole once.

 

Ports/Slots

Burner

 

Tube

 

Pilot

Pilot Air

Inlet

Assembly

Hole

 

Figure 58 - Pilot Inlet Air Hole (Natural Gas Model Shown)

LOGS

If you remove logs for cleaning, refer to Installing Logs, pages 21 and 22, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

CLEANING AND MAINTENANCE

27

Cleaning Pilot Air Inlet Hole

Logs

 

SPECIFICATIONS

 

SERVICE HINTS

 

TECHNICAL SERVICE

 

SPECIFICATIONS

Btu (Variable)

20,000/33,000

 

Type Gas

Natural: (CG)EFP33NR

 

Propane/LP: (CG)EFP33PR

Ignition

Electronic (Automatic)/Piezo (Manual)

 

Natural Gas

Propane/LP Gas

Manifold Pressure

3.5" W.C.

8.0" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

10.5"

14"

Minimum*

5"

11"

Shipping Weight

122 lbs.

122 lbs.

* For input adjustment

 

 

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

for propane/LP units, propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

You can also visit DESA International’s technical service web site at www.desatech.com.

LOGSFor moreSPECIFICATIONSSERVICE HINTSTECHNICAL SERVICEvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background