BUILT-IN FIREPLACE INSTALLATION

INSTALLATION

Conventional Fireplace Installation (Cont.) Built-In Fireplace Installation

19

INSTALLATION

Continued

11.Carefully insert fireplace into cabinet mantel (see Figure 33). Be careful not to scratch or damage hearth base, cabinet man- tel, or any laminate trim on hearth base. Remove protective material from top of hearth base and from front of fireplace (if any). Note: You can secure fireplace to hearth or floor. Open lower louver. Locate screw holes in bottom of base. Tighten wood screws through these holes and into hearth or floor.

12.Check all gas connections for leaks. See Checking Gas Con- nections, pages 17 and 18.

Cabinet

Manual background Mantel

Figure 31 - Installing Cabinet Mantel

Nailing Flanges

Figure 32 - Location of Nailing Flanges (EFP33PR Shown)

BUILT-IN FIREPLACE INSTALLATION

Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. If installing a mantel above the fireplace, you must follow the clearances shown in Figure 37, page 20. Follow the instructions below to install the fireplace in this manner.

 

Actual

Framing

 

 

 

Height

32 3/ "

33"

 

8

 

Front Width

34 5/16"

35 1/2"

Depth

16 11/16"

17 3/4"

1.Frame in rough opening. Use dimensions shown in Figure 34 for the rough opening. If installing in a corner, use dimensions shown in Figure 35 for the rough opening. The height is 33" which is the same as the wall opening above.

2.Install and properly ground GA3555, three-prong 120 volt elec- trical outlet, in fireplace. Follow instructions included in kit (see Accessories, pages 36 and 37).

3.If not already completed, install gas piping to fireplace location. This installation includes an approved flexible gas line (if al- lowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas pip- ing. See Installing Gas Piping to Fireplace Location, page 15.

4.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.

5.Attach flexible gas line to gas supply. See Connecting Fire- place to Gas Supply, page 16.

6.Plug electrical cord(s) into electrical outlet installed in step 2.

7.Carefully insert fireplace into rough opening.

 

 

 

 

 

 

39 3/8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17 3/4"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27 7/8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33"

 

 

 

 

 

 

35 1/2"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55 5/8"

 

 

 

 

 

 

 

 

35 1/2"

 

 

Figure 35 - Rough Opening

 

 

Figure 34 - Rough Opening for

Installing in Wall

for Installing in Corner

Figure 33 - Inserting Fireplace Into Cabinet Mantel (EFP33PR

Shown)

Manual backgroundFor moreManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

108117-01H

Page 19
Image 19
Desa EFP33PR, EFP33NR installation manual Built-Infireplace Installation, Continued