Locating Fireplace

Continued

CAUTION: Do not expose the heater to the elements (such as rain, etc.)

CAUTION: Wear gloves and safety glasses for protection during installation and main- tenance.

Plan where to locate and frame fireplace. Before installation consider the following:

1.Fireplace location must allow for wall and ceiling clearances (see Installation Clear- ances).

2.Fireplace screen should not be exposed to direct sunlight from windows or doors.

3.Unit can be wired for either 120/60 (15 amp circuit) or 240/60 (20 amp circuit). A dedicated circuit should be provided to avoid circuit breaker trips or blown fuses.

Flush Installations are recommended where living space is limited or at a premium. Since space required to enclose fireplace would be located beyond an outside wall, this installation would require additional planning and construction. Check local codes for any restrictions.

Projected Installations can extend any distance into room. A projection may be ideal for a new addition on an existing, finished wall.

Corner Installations make use of space that may not normally be used and provides a wider and more efficient viewing angle and heat distribution.

Internal Wall Installations provide a discrete option for room separation and can also be an ideal addition to an existing wall.

Internal Wall

Corner

Installation

Installation

Flush

Full ProjectionInstallation

Installation

Figure 3 - Possible Installation Locations

Installation

INSTALLATION CLEARANCES

Minimum clearances to combustible construction are:

Top, Back and Sides of Recessed Cabinet 0" Min.

Drywall to Sides of Front Face

0" Min.

Framing at Nailing Flanges

0" Min.

Ceiling to Opening

36" Min.

Floor

0" Min.

Front

36" Min.

Perpendicular Side Wall

10" Min.

Mantel Clearances

For mantel clearances see Figures 4 and 5.

 

Facing Material May

 

Be Noncombustible

 

Wall Treatments or

12" Ref.

Combustible Wood

10 1/2"

Combustible Wood

 

4 1/2"

Mantels and Trims

1 1/2"

May Extend Above

30°

Profile Shown when

Maintained within

 

 

30° Parameter

 

Shown

 

Framed

23"

Material

 

21"

 

17"

Top of Cabinet

15" Min.

 

Note: All Mantel Clearances are Measured from Top of Fireplace Opening

Figure 4 - Mantel Clearances

 

 

 

Edge of

Top View of Fireplace

 

Firebox

3"

Opening

 

 

30° 5"

Safe Zone

 

 

1 3/4" Max.

Combustible

 

 

 

Material Must

 

Minimum 10"

 

Not Overlap

 

 

Front Face

 

from Perpendicular

 

 

 

Side Wall

 

 

Figure 5 - Mantel Side Clearances

122663-01D